Number of the records: 1  

Study of the 16-channel scintillation detector prototype with silicon photomultipliers readout

  1. 1.
    0547008 - ÚJF 2022 RIV US eng C - Conference Paper (international conference)
    Tishevsky, A. V. - Gurchin, Y. V. - Isupov, A. Yu. - Janek, M. - Khrenov, A. N. - Kurilkin, P. - Kushpil, Vasilij - Ladygin, V. P. - Mezhenska, O. - Reznikov, S. G. - Terekhin, A. A.
    Study of the 16-channel scintillation detector prototype with silicon photomultipliers readout.
    AIP Conference Proceedings. Vol. 2377. Maryland: American Institute of Physics Inc., 2021, č. článku 030017. ISBN 978-073544132-3. ISSN 0094-243X.
    [International Scientific Conference on Young Scientists and Specialists /24./ (AYSS 2020). online (RU), 09.11.2020-13.11.2020]
    R&D Projects: GA MŠMT LTT18021
    Institutional support: RVO:61389005
    Keywords : silicon photomultipliers * scintillation detector * prototype
    OECD category: Nuclear physics

    The paper presents measurements of the noise characteristics of silicon photomultipliers in the temperature range from 27.7 °C to 39.1 °C, as well as study of the response of the detector prototypes with Ketek and Hamamatsu SiPM readout to the light source at different voltages. The prototype with SiPM readout from Ketek was tested at the Joint Institute for Nuclear Research Nuclotron deuteron beam at the energy of 4 GeV/nucleon. Time resolution and amplitude of the signal have been estimated.
    Permanent Link: http://hdl.handle.net/11104/0323373

     
     
Number of the records: 1  

  This site uses cookies to make them easier to browse. Learn more about how we use cookies.