Screen-printed amalgam electrodes

  1. 1.
    0544959 - ÚFCH JH 2022 RIV CH eng J - Journal Article
    Josypčuk, Bohdan - Langmaier, Jan - Tvorynska, Sofiia
    Screen-printed amalgam electrodes.
    Sensors and Actuators B - Chemical. Roč. 347, NOV 2021 (2021), č. článku 130583. E-ISSN 0925-4005
    R&D Projects: GA ČR(CZ) GA20-01589S
    Institutional support: RVO:61388955
    Keywords : electrochemistry * screen-printed electrodes * silver amalgam
    OECD category: Electrochemistry (dry cells, batteries, fuel cells, corrosion metals, electrolysis)
    Impact factor: 9.221, year: 2021
    Method of publishing: Limited access

    Silver amalgam screen-printed electrodes (AgA-SPEs) were designed, prepared and tested for the first time as perspective representatives among SPEs that allow measuring at high negative potentials. For this purpose, the precise electrochemical (coulometric) preparation procedure for mercury deposition at the silver working electrode surface of the commercial silver-SPE was developed and a universal method of preparing amalgam electrodes from different metal-SPEs was described. An optimal electrolyzer construction for the mercury deposition, electrolyte composition, electrolysis potential, and a way to activate the electrode surface for its uniform coverage by mercury were proposed. The effect of the mercury content in amalgam on the potential of hydrogen evolution (PHE) at AgA-SPEs was investigated. The maximum PHE value (−1979 ± 4 mV, RSD = 0.17 %, N = 5) was found on AgA-SPE with 50 % (w/w) of Hg content in 0.1 mol L−1 NaOH, which is more negative than in the case of the original silver-SPE for 387 mV (−1592 ± 12 mV, RSD = 0.69 %, N = 5). Determination of the iodine content in iodinated table salt was used for the AgA-SPEs practical testing. Measurement parameters were optimized for three electrochemical cell arrangements: i) the electrodes area of AgA-SPE was covered by 50 μL of the sample solution and differential pulse voltammetric (DPV) measurements were carried out, ii) 3-electrode batch arrangement with only working electrode from AgA-SPE connected with an analyzer for DPV-measurements, iii) amperometric measurements in a flow system. The results of iodine analysis by all three methods were consistent with the manufacturer declared values.


    Permanent Link: http://hdl.handle.net/11104/0321745

     
    FileDownloadSizeCommentaryVersionAccess
    0544959.pdf21.5 MBPublisher’s postprintrequire
     
Number of the records: 1  

  This site uses cookies to make them easier to browse. Learn more about how we use cookies.