Number of the records: 1  

LIBS analysis of samples from the COMPASS vacuum chamber after liquid metal experiments – Li campaign

  1. 1.
    0533925 - ÚFP 2021 RIV US eng J - Journal Article
    Veis, P. - Atikkuke, S. - Marin Roldan, A. - Dwivedi, V. - Veis, M. - Bartoň, Petr - Jeřáb, Martin - Dejarnac, Renaud
    LIBS analysis of samples from the COMPASS vacuum chamber after liquid metal experiments – Li campaign.
    Nuclear Materials and Energy. Roč. 25, December (2020), č. článku 100809. E-ISSN 2352-1791
    R&D Projects: GA MŠMT(CZ) LM2018117; GA MŠMT(CZ) EF16_019/0000768
    EU Projects: European Commission(XE) 633053 - EUROfusion
    Institutional support: RVO:61389021
    Keywords : compass * Li * libs * Liquid metals * Plasma-facing materials * Tokamak
    OECD category: Fluids and plasma physics (including surface physics)
    Impact factor: 2.320, year: 2020
    Method of publishing: Open access
    https://www.sciencedirect.com/science/article/pii/S2352179120300843?via%3Dihub

    To overcome the erosion of the plasma-facing materials (PFMs) inside a fusion reactor, liquid metals such as lithium or tin are being explored as potential PFMs in fusion reactors due to their several advantages such as self-repair or high-power exhaust capability. Lithium can reduce the oxygen and carbon impurity contamination by chemically binding these species to the wall. Thus, experiments of power handling performance with a special liquid metal (Li) divertor module based on the capillary porous system technology were performed in the tokamak COMPASS. The elemental analysis of 14 screw samples located around the vacuum vessel provides information about the migration of evaporated/redeposited liquid elements. The main goal of this work is to characterize and quantify screws containing Li-based coating by LIBS by measuring the quantitative elemental composition. The studied samples were Li-coated Ni-Cr-based screws. The laser ablation was performed in air at atmospheric pressure using a 5 ns pulse Nd:YAG laser at 1064 nm. Suitable Li I, Ca I-II, and Fe I spectral lines were employed for the evaluation of the electron temperature of the plasma using multi-elemental Saha-Boltzmann plots. The electron density was obtained from the Stark broadening of the Hα spectral line. The elemental content of each sample was then obtained by calibration-free LIBS (CF-LIBS).
    Permanent Link: http://hdl.handle.net/11104/0312154

     
     
Number of the records: 1  

  This site uses cookies to make them easier to browse. Learn more about how we use cookies.