Number of the records: 1  

Near-Linear Scaling in DMRG-Based Tailored Coupled Clusters: An Implementation of DLPNO-TCCSD and DLPNO-TCCSD(T)

  1. 1.
    0524283 - ÚFCH JH 2021 RIV US eng J - Journal Article
    Lang, Jakub - Antalík, Andrej - Veis, Libor - Brandejs, Jan - Brabec, Jiří - Legeza, Ö. - Pittner, Jiří
    Near-Linear Scaling in DMRG-Based Tailored Coupled Clusters: An Implementation of DLPNO-TCCSD and DLPNO-TCCSD(T).
    Journal of Chemical Theory and Computation. Roč. 16, č. 5 (2020), s. 3028-3040. ISSN 1549-9618. E-ISSN 1549-9626
    R&D Projects: GA ČR(CZ) GA18-24563S; GA ČR GA16-12052S; GA ČR(CZ) GJ18-18940Y; GA MŠMT(CZ) LTAUSA17033
    Grant - others:Ga MŠk(CZ) LM2015070; AV ČR(CZ) MTA-19-04
    Program: Bilaterální spolupráce
    Institutional support: RVO:61388955
    Keywords : Energy * Basis sets * Quantum mechanics * Chemical calculations
    OECD category: Physical chemistry
    Impact factor: 6.006, year: 2020
    Method of publishing: Limited access

    We present a new implementation of density matrix renormalization group based tailored coupled clusters method (TCCSD), which employs the domain-based local pair natural orbital approach (DLPNO). Compared to the previous local pair natural orbital (LPNO) version of the method, the new implementation is more accurate, offers more favorable scaling, and provides more consistent behavior across the variety of systems. On top of the singles and doubles, we include the perturbative triples correction (T), which is able to retrieve even more dynamic correlation. The methods were tested on three systems: tetramethyleneethane, oxo-Mn(Salen), and iron(II)–porphyrin model. The first two were revisited to assess the performance with respect to LPNO-TCCSD. For oxo-Mn(Salen), we retrieved between 99.8 and 99.9% of the total canonical correlation energy which is an improvement of 0.2% over the LPNO version in less than 63% of the total LPNO runtime. Similar results were obtained for iron(II)–porphyrin. When the perturbative triples correction was employed, irrespective of the active space size or system, the obtained energy differences between two spin states were within the chemical accuracy of 1 kcal/mol using the default DLPNO settings.
    Permanent Link: http://hdl.handle.net/11104/0308654

     
    FileDownloadSizeCommentaryVersionAccess
    0524283.pdf12.3 MBPublisher’s postprintrequire
     
Number of the records: 1  

  This site uses cookies to make them easier to browse. Learn more about how we use cookies.