Number of the records: 1
Low-molecular-mass nitrophenol-based compounds suitable for the effective tracking of pH gradient in isoelectric focusing
- 1.0506061 - ÚIACH 2020 RIV NL eng J - Journal Article
Duša, Filip - Moravcová, Dana - Šlais, Karel
Low-molecular-mass nitrophenol-based compounds suitable for the effective tracking of pH gradient in isoelectric focusing.
Analytica Chimica Acta. Roč. 1076, OCT (2019), s. 144-153. ISSN 0003-2670. E-ISSN 1873-4324
R&D Projects: GA MV VI20172020069; GA ČR(CZ) GA19-00742S
Institutional support: RVO:68081715
Keywords : Isoelectric point * marker * focusing
OECD category: Analytical chemistry
Impact factor: 5.977, year: 2019
Method of publishing: Limited access
The article presents a comparative study dealing with characterization of 44 nitrophenol-based compounds synthesized by the Mannich reaction which pI values cover a pH range from 3.2 to 10.4. The values of pIs of all the presented nitrophenolbased compounds were precisely determined by capillary isoelectric focusing technique.
Permanent Link: http://hdl.handle.net/11104/0297353
File Download Size Commentary Version Access 0506061_IR.pdf 10 2.7 MB Author’s postprint require