Number of the records: 1  

Analysis of acoustic emission source location precision for general sensor configurations

  1. 1.
    0498347 - ÚT 2019 RIV CZ eng C - Conference Paper (international conference)
    Chlada, Milan - Gális, P. - Převorovský, Zdeněk
    Analysis of acoustic emission source location precision for general sensor configurations.
    Defektoskopie 2018 NDE for Safety. Brno: Brno University of Technology, 2018 - (Pazdera, L.; Mazal, P.; Turek, P.), s. 182-192. ISBN 978-80-214-5684-6.
    [International Conference and NDT Exhibition Defektoskopie 2018 NDE for Safety 2018 /48./. Praha (CZ), 06.11.2018-08.11.2018]
    R&D Projects: GA ČR(CZ) GA17-22615S
    Institutional support: RVO:61388998
    Keywords : acoustic emission * AE source location * geometrical effects
    OECD category: Applied mechanics

    Proper sensor placement is the crucial step and a premise for precise acoustic emission (AE) source location estimate. Using the algorithm for finding the shortest ways in discretely defined bodies it is possible to design three parallel tools how to evaluate problematic areas, namely the location sensitivity, similarity and ambiguity maps, available even for discontinuous or anisotropic bodies. To check the numerical forecast of localization capabilities for given sensor configuration, theoretical results were compared with the data measured on the real steam pressure vessel.