Quantum dots as chemiluminescence enhancers tested by sequential injection technique: Comparison of flow and flow-batch conditions

  1. 1.
    0468753 - ÚIACH 2018 RIV NL eng J - Journal Article
    Sklenářová, H. - Voráčová, Ivona - Chocholouš, P. - Polášek, M.
    Quantum dots as chemiluminescence enhancers tested by sequential injection technique: Comparison of flow and flow-batch conditions.
    Journal of Luminescence. Roč. 184, APR (2017), s. 235-241. ISSN 0022-2313. E-ISSN 1872-7883
    Institutional support: RVO:68081715
    Keywords : quantum dots * chemiluminescence * sequentialinjectionanalysis
    OECD category: Analytical chemistry
    Impact factor: 2.732, year: 2017

    The effect of Quantum Dots (QDs) with different emission wavelengths
    (520–640nm) and different surface modifications (mercaptopropionic, mercaptoundecanoic, thioglycolic acids and
    mercaptoethylamine) on permanganate-induced and luminol–hydrogen peroxide chemiluminescence (CL) was studied in detail by a sequential injection technique using a spiral detection flow cell and a flow- batch detection cell operated in flow and stop-flow modes.

    Permanent Link: http://hdl.handle.net/11104/0266579

     
    FileDownloadSizeCommentaryVersionAccess
    0468753_IR.pdf3471.2 KBOtherrequire
     