Number of the records: 1  

Coanda effect in valves

  1. 1.
    0468089 - ÚT 2017 CZ eng C - Conference Paper (international conference)
    Uruba, Václav - Procházka, Pavel P. - Skála, Vladislav
    Coanda effect in valves.
    Experimental Fluid Mechanics 2016 - Conference Proceedings. Liberec: Technical University of Liberec, 2016 - (Dančová, P.), s. 879-883
    [Experimental Fluid Mechanics 2016. Mariánské Lázně (CZ), 15.11.2016-18.11.2016]
    R&D Projects: GA TA ČR(CZ) TA04020129; GA TA ČR(CZ) TA04011437
    Institutional support: RVO:61388998
    Keywords : diffuser * coanda effect * OPD
    Subject RIV: BK - Fluid Dynamics

    Coanda effect takes place in flow within valves diffuser for certain conditions. The valve plug in
    half-closed position forms wall-jet, which could be stable or instable, depending on geometry and other
    conditions. This phenomenon was subject of experimental study using time-resolved PIV technique. For the acquired data analysis the special spatio-temporal methods have been used.
    Permanent Link: http://hdl.handle.net/11104/0267332

     
     