Number of the records: 1
Effects of selected operational parameters on efficacy and selectivity of electromembrane extraction. Chlorophenols as model analytes
- 1.0431195 - ÚIACH 2015 RIV DE eng J - Journal Article
Šlampová, Andrea - Kubáň, Pavel - Boček, Petr
Effects of selected operational parameters on efficacy and selectivity of electromembrane extraction. Chlorophenols as model analytes.
Electrophoresis. Roč. 35, č. 17 (2014), s. 2429-2437. ISSN 0173-0835. E-ISSN 1522-2683
R&D Projects: GA ČR(CZ) GA13-05762S
Institutional support: RVO:68081715
Keywords : electromembrane extraction * chlorophenols * extraction selectivity
Subject RIV: CB - Analytical Chemistry, Separation
Impact factor: 3.028, year: 2014
A comprehensive quantitative study, based also on measurements of electric charge passed through the EME system, was carried out, which demonstrates that apart from the pH value, also the nature of counter-ions in donor and acceptor solution plays a significant role in the electrically induced transfer of charged analytes across supported liquid membranes.
Permanent Link: http://hdl.handle.net/11104/0235810
File Download Size Commentary Version Access 0431195_IR.pdf 1 839.4 KB Other require