    Verification of k (0)-NAA results at the LVR-15 reactor in A similar to eA3/4 with the use of Au plus Mo plus Rb( plus Zn) monitor set.
    Journal of Radioanalytical and Nuclear Chemistry. Roč. 300, č. 2 (2014), s. 473-480. ISSN 0236-5731. E-ISSN 1588-2780
    R&D Projects: GA ČR(CZ) GBP108/12/G108; GA MŠMT(XE) LM2011019
    Institutional support: RVO:61389005
    Keywords : neutron activation analysis * k(0) standardization * neutron flux parameters * monitor set for long irradiations
    Subject RIV: CB - Analytical Chemistry, Separation
    Impact factor: 1.034, year: 2014

    Long-time experience in neutron flux monitoring on irradiation in the LVR-15 research reactor in A similar to eA3/4 proved that Au+Mn+Rb and Au+Mo+Rb(+Zn) monitor sets for short and long irradiation, respectively, are more suitable in our conditions than the most frequently used Au+Zr set. The advantages of the former monitor set have been described previously, in the present work we discuss the advantages of the latter monitor set for long irradiations in varying active core configurations of the LVR-15 reactor. The successful application of the Au+Mo+Rb(+Zn) monitor set has been verified by comparative determination of the neutron flux parameters alpha (epithermal flux distribution parameter), f (thermal-to-epithermal neutron flux ratio), and F (c,Au) (comparator factor) using this and the Au+Zr monitor set, and by analyses of certified reference materials, namely NIST SRMs 1547 Peach Leaves, 2711 Montana Soil, and 1633b Trace Elements in Coal Fly Ash.
    Permanent Link: http://hdl.handle.net/11104/0233803

     
     
Number of the records: 1  

  This site uses cookies to make them easier to browse. Learn more about how we use cookies.