Basamatikum - Aerosol Spectrometer Tested by the End Users in the Technical Museum in Brno
- 1.0428096 - ÚCHP 2015 RIV CZ eng O - Others
Grossmannová, H. - Mašková, Ludmila - Ondráček, Jakub - Smolík, Jiří
Basamatikum - Aerosol Spectrometer Tested by the End Users in the Technical Museum in Brno.
Programme and Abstract book. Prague: -, 2014. s. 31. ISBN N
R&D Projects: GA MK DF11P01OVV020
Keywords : aerosol particles * indoor environment * museum
Subject RIV: CF - Physical ; Theoretical Chemistry
Time behavior of submicron particles concentration showed that visitors did not affect the fine particle concentration and that these particles mostly came from outdoor environment. The average concentration of indoor particles was 1.5 x 103/cm3, which was about 3.5 times lower then outdoors. Indoor concentration of coarse particles showed periodical rising starting at the beginning of the opening hours, with maxima achieved at the end of visiting hours and subsequent decrease to initial values (Fig. 1). Bigger maximal concentrations were recorded during the first school week and then every weekend.
Permanent Link: http://hdl.handle.net/11104/0233509
File Download Size Commentary Version Access SKMBT_C22014051309534.pdf 33 478.3 KB Publisher’s postprint open-access
Number of the records: 1