Number of the records: 1
Application of the Electrodiffusion Method forNnear-Wall Flow Diagnostics
- 1.0423633 - ÚCHP 2014 RIV CZ eng C - Conference Paper (international conference)
Tihon, Jaroslav
Application of the Electrodiffusion Method forNnear-Wall Flow Diagnostics.
Conference Proceedings. Liberec: Polypress, 2014, s. 706-712. ISBN 978-80-260-5375-0.
[International Conference Experimental Fluid Mechanics 2013. Kutná Hora (CZ), 19.11.2013-22.11.2013]
R&D Projects: GA ČR(CZ) GAP101/12/0585
Institutional support: RVO:67985858
Keywords : electrodiffusion method * wavy film flow * near wall
Subject RIV: CI - Industrial Chemistry, Chemical Engineering
The electrodiffusion method is presented as a measuring technique suitable for the flow measurement done in close proximity of the wall, thus in the region difficultly accessible by standard anemometric techniques (e.g. PIV, LDA). The experimental results obtained in different flow configurations (backward-facing step flow, wavy film flow, turbulent channel flow, rising Taylor bubbles) document application capabilities of this technique, e.g. for mapping of wall shear stresses, delimitation of stable flowrecirculation zones, detection of short-time reversal of the near-wall flow, investigation of the near-wall turbulence, or detection of moving fluid particles. A new technology of sensor fabrication based on photolithography is introduced and possible applications of microsensors in microfluidic devices discussed.
Permanent Link: http://hdl.handle.net/11104/0229786
File Download Size Commentary Version Access SKMBT_C22014011511300.pdf 58 3.1 MB Publisher’s postprint open-access