Number of the records: 1  

Experimental Determination of Neutron Room Background at the NPI Cyclotron U-120M

  1. 1.
    0421817 - ÚJF 2014 RIV CZ eng C - Conference Paper (international conference)
    Štefánik, M. - Bém, Pavel - Honusek, Milan - Katovsky, K. - Majerle, Mitja - Novák, Jan - Šimečková, Eva
    Experimental Determination of Neutron Room Background at the NPI Cyclotron U-120M.
    International Scientific Conference on Electric Power Engineering. Ostrava: VSB-Tech Univ Ostrava, 2012 - (Drapela, J.; Macháček, J.), s. 1275-1279. ISBN 978-80-214-4514-7.
    [13th International Scientific Conference Electric Power Engineering (EPE). Brno (CZ), 23.05.2012-25.05.2012]
    Institutional support: RVO:61389005
    Keywords : activation detector * external neutron generator * gamma-ray spectroscopy * isochronous Cyclotron U-120M * neutron room background * neutron spectrum reconstruction * reaction rate * white neutron spectrum
    Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders

    During the operation of external neutron generators of the Nuclear Physics Institute of The Academy of Sciences of the Czech Republic, the neutron room background is produced in cyclotron hall. To assess this effect, the neutron room background was measured using the activation method of dosimetry foils. To unfold the background spectrum from the set of measured reaction rates, the method of spectrum description by the special analytical function was employed.
    Permanent Link: http://hdl.handle.net/11104/0228121

     
     
Number of the records: 1  