Number of the records: 1  

Body Surface Potential Mapping - the Application in Men from the Twenty Years Lasting Epidemiological Study

  1. 1.
    0404933 - UIVT-O 20030053 RIV NL eng C - Conference Paper (international conference)
    Tomečková, Marie - Boudík, F. - Aschermann, M. - Zvárová, Jana - Anger, Z. - Stanovská, Zuzana
    Body Surface Potential Mapping - the Application in Men from the Twenty Years Lasting Epidemiological Study.
    The New Navigators: from Professional to Patient. Amsterdam: IOS Press, 2003 - (Baud, R.; Fieschi, M.; Le Beux, P.; Ruch, P.), s. 352-357. Studies in Technology and Informatics, 95. ISBN 1-58603-347-6. ISSN 0926-9630.
    [MIE 2003. StMalo (FR), 04.05.2003-07.05.2003]
    R&D Projects: GA MŠMT LN00B107
    Keywords : body surface potential mapping * primary preventive study * risk factors of atherosclerosis
    Subject RIV: BB - Applied Statistics, Operational Research

    Body surface potential mapping (BSPM) is non-invasive diagnostic method detected local changes of the heart electrical field. The method is a very useful in epidemiological studies of atherosclerosis, namely with coronary localization, in clinical practice, and in the biomedical research too. The method was performed in the group of 108 men in the frame of the primary preventive study of the risk factors of atherosclerosis in middle-aged men (STULONG). The results on BSPM were discussed.
    Permanent Link: http://hdl.handle.net/11104/0125153

     
     

Number of the records: 1  

  This site uses cookies to make them easier to browse. Learn more about how we use cookies.