Number of the records: 1
Erratum to Added Mass of Dispersed Particles by CFD: Further Results [Chem. Eng.Sci.97(2013)366–375]
- 1.0393370 - ÚCHP 2014 GB eng J - Journal Article
Šimčík, Miroslav - Růžička, Marek
Erratum to Added Mass of Dispersed Particles by CFD: Further Results [Chem. Eng.Sci.97(2013)366–375].
Chemical Engineering Science. Roč. 99, AUG 9 (2013), s. 139-140. ISSN 0009-2509. E-ISSN 1873-4405
Institutional support: RVO:67985858
Keywords : bubble columns * dispersion * hydrodynamics
Subject RIV: CI - Industrial Chemistry, Chemical Engineering
Impact factor: 2.613, year: 2013
The Publisher regrets tha terrors appeared in Eq. (1.1) and the two sentences following the equation. The correct equation and following sentences appear below. The conversion between the vectors of acceleration and force is mediated via atensorial quantity called the added mass, where ρ is fluid density, V is particle volume,and C is the tensor of the added mass coefficients (also :inertia coefficients). In flow situations with enough symmetry,tensor C becomes a mere scalar,a positive real number—the added mass coefficient C. Secondly,there was an error in the alignment of row s32-33 in Table3.
Permanent Link: http://hdl.handle.net/11104/0222909
Number of the records: 1