Number of the records: 1  

Changes in Heart Rate in Patients with a Pacemaker do not Affect Cardiac Output

  1. 1.
    0386611 - ÚPT 2013 RIV US eng C - Conference Paper (international conference)
    Vondra, Vlastimil - Soukup, L. - Jurák, Pavel - Halámek, Josef - Viščor, Ivo - Lipoldová, J. - Leinveber, Pavel
    Changes in Heart Rate in Patients with a Pacemaker do not Affect Cardiac Output.
    Engineering in Medicine and Biology Society (EMBC), 2012 34th Annual International Conference of the IEEE. Piscataway: IEEE, 2012, s. 511. ISBN 978-1-4244-4119-8.
    [EMBC 2012. Annual International Conference of the IEEE Engineering in Medicine and Biology Society /34./. San Diego (US), 28.08.2012-01.09.2012]
    R&D Projects: GA MŠMT ME09050; GA MŠMT ED0017/01/01; GA ČR GAP102/12/2034
    Institutional support: RVO:68081731
    Keywords : Pacemaker * Changes in Heart Rate * Cardiac Output
    Subject RIV: FA - Cardiovascular Diseases incl. Cardiotharic Surgery

    We are presenting a study measuring the dependence of cardiac out¬put on heart rate during rest in patients with an implanted pacemaker. The heart rate was changed artificially by pacemaker programming. No exercise and no drugs were applied. The measurement of cardiac out¬put was performed by electrical impedance cardiography. The results of 44 patients are presented in this study.