An investigation of suitable bag materials for the collection and storage of breath samples containing hydrogen cyanide

  1. 1.
    0384158 - ÚFCH JH 2013 RIV GB eng J - Journal Article
    Gilchrist, F. J. - Razavi, C. - Webb, A. K. - Jones, A.M. - Španěl, Patrik - Smith, D. - Lenney, W.
    An investigation of suitable bag materials for the collection and storage of breath samples containing hydrogen cyanide.
    Journal of Breath Research. Roč. 6, č. 3 (2012), 036004. ISSN 1752-7155. E-ISSN 1752-7163
    Institutional support: RVO:61388955
    Keywords : tube mass spectrometry * cystic fibrosis * pseudomonas aeruginosa
    Subject RIV: CF - Physical ; Theoretical Chemistry
    Impact factor: 2.571, year: 2012

    The SPACE study will assess exhaled breath hydrogen cyanide (HCN) concentrations as a marker of Pseudomonas aeruginosa (PA) infection in 240 children with cystic fibrosis (CF). It will use off-line selected ion flow tube mass spectrometry (SIFT-MS) analysis and so we needed to investigate which breath sampling bag material to use, the maximum storage time before analysis and the benefit of warming the bag samples. We studied 15 children with CF, 8 had chronic PA infection and 7 did not. Each exhaled directly into the instrument (on-line) and also into two 25 mu m thick Nalophan (25N), two 70 mu m Nalophan (70N) and two Tedlar (R) bags. Bags were stored at 20 or 37 degrees C. HCN concentrations were analysed at 1, 6, 24 and 48 h (off-line). Acetone and water vapour concentrations were also measured in parallel. Correlation between on-line and off-line concentrations measured by SIFT-MS was better for all compounds and bag types at 37 degrees C. The median (IQR) on-line HCN concentration was 8.9(4.4-13.7) parts per billion by volume, ppbv. Both on-line and off-line HCN concentrations were significantly higher in patients with PA infection than those without. At 37 degrees C the correlation between on-line and off-line HCN concentrations was good up to 6 h in the 25N bag (R-2 = 0.79) and up to 24 h for the 70N and Tedlar bags (R-2 = 0.82 and 0.86). The correlation between on- and off-line acetone concentrations at 37 degrees C was good up to 24 h in 25N, 70N and Tedlar bags (R-2 = 0.89, 0.93 and 0.97). In all three types of bag the water vapour concentration fell quickly and by 24 h was equivalent to that of lab air. Samples stored in Tedlar or 70N bags, warmed to 37 degrees C and analysed within 24 h, give HCN and acetone concentrations which correlate well with on-line measurements.
    Permanent Link: http://hdl.handle.net/11104/0213887

     
     
Number of the records: 1  

  This site uses cookies to make them easier to browse. Learn more about how we use cookies.