Low cost alternative of high speed visible light camera for tokamak experiments

  1. 1.
    0382736 - ÚFP 2013 RIV US eng J - Journal Article
    Odstrčil, T. - Odstrčil, Michal - Grover, O. - Svoboda, V. - Ďuran, Ivan - Mlynář, Jan
    Low cost alternative of high speed visible light camera for tokamak experiments.
    Review of Scientific Instruments. Roč. 83, č. 10 (2012), 10E505-10E505. ISSN 0034-6748. E-ISSN 1089-7623.
    [Topical Conference High-Temperature Plasma Diagnostics/19./. Monterey, 06.05.2012-10.05.2012]
    Institutional research plan: CEZ:AV0Z20430508
    Keywords : Plasma * tokamak * diagnostic * high speed camera * GOLEM
    Subject RIV: BL - Plasma and Gas Discharge Physics
    Impact factor: 1.602, year: 2012
    http://dx.doi.org/10.1063/1.4731003

    We present design, analysis, and performance evaluation of a new, low cost and high speed visible-light camera diagnostic system for tokamak experiments. The system is based on the camera Casio EX-F1, with the overall price of approximately a thousand USD. The achieved temporal resolution is up to 40 kHz. This new diagnostic was successfully implemented and tested at the university tokamak GOLEM (R = 0.4 m, a = 0.085 m, BT~0.5 T, Ip~4 kA). One possible application of this new diagnostic at GOLEM is discussed in detail. This application is tomographic reconstruction for estimation of plasma position and emissivity.
    Permanent Link: http://hdl.handle.net/11104/0212870

     
     