Number of the records: 1  

Analysis of Steady-State Operation of Induction Generators

  1. 1.
    0329189 - ÚT 2010 RIV CZ eng C - Conference Paper (international conference)
    Schreier, Luděk - Bendl, Jiří - Chomát, Miroslav - Skalka, Miroslav
    Analysis of Steady-State Operation of Induction Generators.
    Proceedings of the International Conference on Low Voltage Electrical Machines. Brno: Brno University of Technology, 2008, s. 102-105. ISBN 978-80-214-3795-1.
    [International Conference on Low Voltage Electrical Machines. Brno (CZ), 06.11.2008]
    R&D Projects: GA ČR GA102/08/0424
    Institutional research plan: CEZ:AV0Z20570509
    Keywords : induction generator * circle diagram * magnetic circuit over-saturation
    Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering

    The paper deals with the problems associated with the estimation of the magnetizing current in generator operation of induction machines. The aim of this paper is to show possible rise of over-saturation of magnetic circuit in induction generators. The results may be used for more precise specification of parameters of an induction machine in different operating modes.