Number of the records: 1
Detection of aqueous solutions of toluene by means of an IGI fiber in a flow cell
- 1.0304014 - URE-Y 20020053 GB eng A - Abstract
Chomát, Miroslav - Berková, Daniela - Matějec, Vlastimil - Kašík, Ivan - Kuncová, Gabriela
Detection of aqueous solutions of toluene by means of an IGI fiber in a flow cell.
[Manchester]: [University of Manchester], 2002. Europt(r)ode VI. Book of abstracts. s. 149
[European Conference on Optical Chemical Sensors and Biosensors EUROPT(R)ODE /6./. 07.04.2002-10.04.2002, Manchester]
R&D Projects: GA ČR GA102/99/0548
Institutional research plan: CEZ:AV0Z2067918
Keywords : optical fibres * chemical sensors * optical sensors * sensitivity
Subject RIV: JB - Sensors, Measurment, Regulation
The studied optical detection of hydrocarbons in waste waters is based on their diffusion from the aqueous solution into the fiber cladding, which causes changes of the refractive index and optical absorption coefficient of the fiber cladding, leading to changes of the fiber output power. The dependence of the fiber response on the velocity of the flow of the agueous solution of toluene in the flow cell has been investigated. Instead of a commonly used PCS fiber, a fiber with an inverted-graded-index /IGI/ profile was employed.
Permanent Link: http://hdl.handle.net/11104/0114158