Biocompatibility of C-C composites covered with PyC and p-HEMA

  1. 1.
    0207819 - USMH-B 20020226 RIV PL eng J - Journal Article
    Burešová, Margit - Balík, Karel - Machovič, V. - Novotná, M. - Pešáková, V. - Hulejová, H. - Sochor, M.
    Biocompatibility of C-C composites covered with PyC and p-HEMA.
    Engineering of Biomaterials. č. 20 (2002), s. 3-5. ISSN 1429-7248
    R&D Projects: GA ČR GA106/00/1407
    Institutional research plan: CEZ:AV0Z3046908
    Keywords : biocompatibility * C-C composites
    Subject RIV: JI - Composite Materials

    The biocompatibility of C-C composites covered with PyC and p-HEMA was tested in vitro tests. These tests proved three times higher metabolic activity of cells cultured on C-C composite with p-HEMA in comparison with the control surface. There was no significant difference in inelammatory cytokine levels between the samples of C-C composite and C-C composite with p-HEMA.