Number of the records: 1
Large-scale separation of magnetic bioaffinity adsorbents
- 1.0170577 - UEK-B 20013037 RIV NL eng J - Journal Article
Šafařík, Ivo - Ptáčková, Lucie - Šafaříková, Miroslava
Large-scale separation of magnetic bioaffinity adsorbents.
Biotechnology Letters. Roč. 23, - (2001), s. 1953-1956. ISSN 0141-5492. E-ISSN 1573-6776
Institutional research plan: CEZ:AV0Z6087904
Keywords : magnetic adsorbents * magnetic separation
Subject RIV: EI - Biotechnology ; Bionics
Impact factor: 0.915, year: 2001
Flat magnetic separator was used to separate magnetic bioaffinity adsorbents from litre volumes of suspensions. Both magnetic cross-linked erythrocytes and magnetic chitosan were efficiently separated; at least 95 % adsorbent recovery was achieved at maximum flow rate (1680 ml/min). Using this system low amounts of trypsin were concentrated from large sample volumes using magnetic erythrocytes as affinity adsorbent.
Permanent Link: http://hdl.handle.net/11104/0067661
Number of the records: 1