Number of the records: 1
Te(R, t) measurements using electron Bernstein wave thermal emission on NSTX
- 1.0043571 - ÚFP 2007 RIV US eng J - Journal Article
Diem, S.J. - Taylor, G. - Efthimion, P.C. - LeBlanc, P.C. - Carter, M. - Caughman, J. - Wilgen, J.B. - Harvey, R.W. - Preinhaelter, Josef - Urban, Jakub
Te(R, t) measurements using electron Bernstein wave thermal emission on NSTX.
[Měření Te(R, t) na NSTX pomocí termální emise elektronových Bernsteinových vln.]
Review of Scientific Instruments. Roč. 77, č. 10 (2006), 10E919, 1-10E919,4. ISSN 0034-6748. E-ISSN 1089-7623.
[Topical Conference on High-Temperature Plasma Diagnostics/16th./. Williamsburg, Virginia, 7.5.2006-11.5.2006]
Institutional research plan: CEZ:AV0Z20430508
Keywords : Overdense plasma * Conversion * Emission * Excitation * Tokamaks * Diagnostics
Subject RIV: BL - Plasma and Gas Discharge Physics
Impact factor: 1.541, year: 2006
http://link.aip.org/link/?RSI/77/10E919
A significant upgrade to the previous NSTX EBW emission diagnostic to measure thermal EBW emission via the oblique B-X-O mode conversion process has been completed. The new EBW diagnostic consists of two remotely steerable, quad-ridged horn antennas, each of which is coupled to a dual channel radiometer. Fundamental (8–18 GHz) and second and third harmonic (18–40 GHz) thermal EBW emission and polarization measurements can be obtained simultaneously.
Bylo dosaženo podstatné zlepšení předchozí diagnostiky měřící termální EBW emisi z NSTX pomocí procesu šikmé EBW-X-O konverze. Nová EBW diagnostika se skládá ze dvou dálkově řízených čtyř hřebenových trychtýřových antén, z nichž každá je připojena k dvoukanálovému radiometru. Základní (8-18 GHz) a druhá a třetí harmonická termální EBW emise spolu s měřením polarizace můžeme získat současně.
Permanent Link: http://hdl.handle.net/11104/0136529
Number of the records: 1