A large volume injection procedure for GC-MS determination of PAHs and PCBs
- 1.0021360 - ÚIACH 2006 RIV DE eng J - Journal Article
Večeřa, Zbyněk - Bartošíková, Anna - Sklenská, Jana - Mikuška, Pavel
A large volume injection procedure for GC-MS determination of PAHs and PCBs.
[Large volume injection metoda pro GC-MS stanovení PAHs a PCBs.]
Chromatographia. Roč. 61, 3/4 (2005), s. 197-200. ISSN 0009-5893. E-ISSN 1612-1112
R&D Projects: GA ČR GA526/03/1182; GA ČR GA525/04/0011
Keywords : large-volume injection * GC-MS * soil samples
Subject RIV: CB - Analytical Chemistry, Separation
Impact factor: 0.959, year: 2005
A simple on-column injection procedure for large volume of liquid samples for the GC-MS determination of traces of PAHs and PCBs in environmental samples (soils) has been optimized. Detection limits were 5-50 ng L-1 of PAHs and 11-44 ng L-1 of PCBs in hexane solution.
Jednoduchý postup pro dávkování velkých objemů kapaliny na kolonu při GC-MS stanovení stopových koncentrací PAHs a PCBs ve vzorcích životního prostředí (půdy) byl optimalizován. Detekční limity byly 5-50 ng L-1 pro PAHs a 11-44 ng L-1 pro PCBs vhexanu.