Number of the records: 1
Comparison of monolithic silica and polymethacrylate capillary columns for LC
- 1.0000451 - ÚIACH 2005 RIV DE eng J - Journal Article
Moravcová, D. - Jandera, P. - Urban, J. - Planeta, Josef
Comparison of monolithic silica and polymethacrylate capillary columns for LC.
[Srovnání monolitických křemenných a polymetakrylátových kapilárních kolon pro LC.]
Journal of Separation Science. Roč. 27, 10-11 (2004), s. 789-800. ISSN 1615-9306. E-ISSN 1615-9314
R&D Projects: GA ČR(CZ) GA203/02/0023
Keywords : monolithic columns * capillary HPLC * column testing
Subject RIV: CB - Analytical Chemistry, Separation
Impact factor: 1.927, year: 2004
Organic polymer monolithic capillary columns were prepared in fused silica capillaries by radical co-polymerization of ethylene dimethacrylate and butyl methacrylate monomers. The chromatographic properties of the organic polymer monolithic columns were compared with those of commercial silica-based particulate and monolithic capillary and analytical HPLC columns.
V křemenných kapilárách byly připraveny pomocí radikálové kopolymerizace etylendimetakrylátu a butylmetakrylátu monolitické kapilární kolony na bázi organického polymeru. Chromatografické vlastnosti těchto kolon byly srovnány s vlastnostmi komerčních kolon na bázi křemene a monolitických kapilárních a analytických kolon pro HPLC