Review

Time-Delay Circuits for Fluidic Oscillators and Pulse Shapers

Institute of Thermomechanics, Czech Academy of Sciences, v.v.i., 182 00 Praha 8, Czech Republic
Energies 2019, 12(16), 3071; https://doi.org/10.3390/en12163071
Submission received: 24 June 2019 / Revised: 16 July 2019 / Accepted: 19 July 2019 / Published: 9 August 2019
(This article belongs to the Special Issue Fluid Mechanics and Thermodynamics: Theory, Methods and Applications)

Abstract

:
Fluidic signals transferred between mutually communicating components of fluidic circuits are nowadays still often in the format of continuously varied value of pressure or flow rate. Especially when transported over longer distances, these simple signals may easily deteriorate due to varying properties they meet in the transmission. An example are friction losses dependent on local temperature. A solution to this signal corruption problem is to encode the signals into flow pulses. Their parameters (such as the number of pulses in a delivered pulse cluster) much less deteriorating during transfer are derived from the time delays generated in delay circuits and oscillators. This paper surveys the basic physical aspects of the fluidic pulse generation and shaping, also presents some examples of circuit design.

1. Introduction

The term fluidics covers generation and handling of fluid flows. Particularly important is pure fluidics, characterised by absence of moved or deformed mechanical components that were earlier, prior to introduction of fluidics, indispensable components of classical hydraulic or pneumatic devices. History of the pure fluidics begun in the second half of the last century when it was developed in an attempt to compete with electronic systems (not successful because electric signals propagate much faster and the electronic devices may be much smaller). Really promising applications for fluidics were thus found only recently. A typical example is the use of fluidic oscillators in chemical and process engineering to generate extremely small bubbles in gas–liquid contacting operations. By pulsating the supplied gas flow, the generated bubbles may be made smaller by as much as several decimal orders of magnitude. Since total collective surface area of the microbubbles is large, the transfer across it more efficient. This is not a new idea, but mechanical oscillators considered for this pulsation task prior to the introduction of fluidics, were expensive and inefficient. Fluidic oscillators—simple, inexpensive and maintenance-free—pulsate the flow quite efficiently. Due to these advantages they found attractive uses in many engineering processes (e.g., References [1,2,3]). Other present uses of fluidics are in the control of fluid flows past aeroplane wings and similar objects (e.g., turbine blades). Jets issuing from nozzles located on object surfaces can suppress undesirable flow separation from the walls or transition into turbulence. These jets may be steady, but demonstrably much more effective is the flow control by unsteady pulsating and/or sweeping jets [4,5,6]. Similar agitation of fluid using a fluidic oscillator is now also applied for increasing the intensity of heat and mass transfer [7,8]. The pulsation disturbs the insulating thermal boundary layer across which the heat has to be transported by slow conduction.
The signals transported between components of a fluidic circuit have now mostly the character of magnitude of flow variables (such as pressure or flow rate). The signal carrying fluid is very often directly those processing the fluid in the circuit’s application. Sometimes this may be a rather extraordinary signal medium, such as molten metals in [9] or the liquid pathogenic biological samples [10] moved in the for analysis circuit. Their properties may thus cause problems in control signal generation. Even with common fluids, like water or air, may arise problems when operating in extraordinary regimes, such as in very small size scales with dominant viscosity or, on the opposite, at large scale flows with turbulence. The small-scale cases are currently of particularly increasing importance in the field of microfluidics [10,11,12,13]. Its typical applications is in acquiring fluid samples—the small size minimizing the disturbance to the investigated object. The handled small amounts in microfluidics also decrease the dangers associated with dangerous fluids (e.g., in analysis of explosives). Small scale also makes easier the circuit manufacturing, which tends to take over the methods originally developed in microelectronics.

2. Signal Encoded in Pulses

Of crucial importance in designing fluidic circuits is the proper handling of the fluidic signals that are transferred between individual parts of the circuit. Variations of properties of the fluid transfer paths (such as variations of local temperature) during the transfer can lead to signal corruption, also caused by the extraordinary fluid properties or extreme conditions.
One approach to the solution of this signal deterioration problem is to encode the information into parameters or numbers of flow pulses. Alternative versions of pulses are presented in Figure 1. The low sensitivity of the pulses to the corruption is the reason behind the basic principle of digital signal coding—in present-day fluidics unusual because of complexity (the advantages of fluidics mostly claimed are its simplicity). A typical example of signals carried by flow pulses is PWM—the pulse width modulation. Its typical output signal history is shown in the top case A in Figure 2. The carried information is encoded there into the durations of the time intervals ΔtON between the ON and OFF switching of the flows. While the flow rate or pressure magnitude may vary due to the action of disturbances, the interval between pulses, like the ΔtOFF in the bottom case B, is influenced much less, if at all.

3. Basic Devices: Amplifiers

Of essential importance for the fluidic pulse generation and shaping is the availability of fluidic amplifiers. It was the invention of the no-moving-part flow amplification that in the middle of sixties of the last century [14,15] started fluidics as a separate branch of technology. It is in contrast with the earlier classical hydraulics and pneumatics, which also can amplify liquid or gas flow rate or pressure but depends on the use of mechanical moved or deformed components. This results in too large size, often a need of maintenance, and complicated (and expensive) manufacturing. In pure fluidics the devices are simply easily made empty cavities.
There is a number of already used or potentially usable fluidic amplification principles. It may suffice to name here just the five most important ones: jet deflection [13] (which is most popular), captive vortex generated by tangential inflow into a cavity [6], colliding flows [16,17], separation of a jet from an attachment wall [14], and transition into turbulence. In the essential principle, fluidic amplification is based on creating inside the amplifier cavity a flowfield characterised by presence of hydrodynamic instability. This creates a sensitive spot where applying a quite weak input action results in a substantial change of the whole flowfield, and in particular, a change in the output terminal. The amplification effect is measured by parameter called gain. It is the ratio of the output (at Y, Figure 3) to the input (at X) values of the same quantity. Amplifiers do exist which for some reason are designed with unity and even sub-unity gain, but this is extremely extraordinary.
Typical present day fluidic amplifiers exhibit a flow gain of the order from 10 to 100. The power used for this amplification effect is delivered from the fluid flow delivered into the supply terminal S. The simplest configuration of an amplifier is schematically presented in the top of Figure 3. The fluid is supplied into the terminal S (usually kept by an external regulator at a constant supplied pressure; though constant flow rate may be also often used). The weak input signal flow is delivered into the input terminal X. Its presence there creates in the output terminal Y a corresponding powerful output effect. What this effect actually is depends on the amplification characteristic of the device. Typical are proportional amplifiers. Their characteristic is linear so that the output is equal to the input multiplied by the value of the gain.
There are—less common—fluidic “turn-down” amplifiers, e.g. as discussed in [17], which decrease the flow passing through them in proportion to the input signal. Much easier to design and develop are the diverter amplifier variants. They need the auxiliary vent terminal V, as shown at the bottom of Figure 3. Through this terminal escapes the fluid which is diverted by the control input action from entering the output terminal Y.
To present an idea about the typical internal configuration, a simple example of an amplifier based on the jet deflection diverter principle is shown schematically in Figure 4. On the right-hand side of this illustration are the two basic detail components of these amplifiers, the collector (a) and the nozzle (b). In the nozzle, the cross-section area available for the fluid flow decreases in the flow direction—while in the diffuser this area increases. In the nozzle the area decrease accelerates the fluid. On leaving the nozzle the fluid generates an accelerated jet. The other components of an amplifier are diffusers, shaped as (a) at the right-hand side of Figure 4. There takes place the opposite conversion: kinetic energy of the captured flow decreases while the pressure rises. Though not absolutely necessary, the diffusers located upstream from the output terminal are useful. Their energy conversions, decreasing the fluid flow velocity, decreases the energetic losses in the signal transfer channels connected to the amplifier—because the losses in the channels are approximately proportional to the square of the channel flow velocity magnitude.
The jet, basic phenomenon taking place in the amplifier shown in Figure 4, is generated using the fluid flow issuing from the supply nozzle S. If there is no input fluid flow entering the control terminal X, the jet is not deflected and leaves through the vent V so that there is no output flow in the exit terminal Y. In proportion to increasing the input signal X delivered into the control nozzle, the jet becomes more deflected and the proportionally increasing part of the jet flow is captured by the collector leading to Y. This jet deflection is a typical case of the flowfield with the weak spot. In this case the spot is located at the base of the jet, immediately downstream from the exit from the supply nozzle.
Many fluidic amplifiers operate in pairs, in a circuit connection that may be called anti-parallel (one amplifier is in the OPEN regime while the other one at the same time is CLOSED). These amplifier pairs are used in fluidics so often that there are commercially available amplifier versions inside consisting of actually two amplifiers integrated into a single object with common internal cavity. The integration means they share some of their components. The two examples of the amplifier pairing presented in Figure 5 show in schematic representation two versions, with amplifiers from Figure 4. The separate two amplifiers at the top of Figure 5 can operate separately as two devices with different tasks. A step in the integration is seen in the version presented in the bottom part of Figure 5. The two amplifiers there share the common supply nozzle—and also the deflected jet which this nozzle generates. As a reminder of the two-channel origin, there are two separate control nozzles and also the corresponding pair of collectors. In principle there is no need to have a pair of vents V because the fluid in this case has enough opportunities for leaving through the two output terminals Y1 and Y2. It should be noted that the input and output terminals with the same index (e.g., the index 1 in X1 and Y1) are on opposite sides of the symmetry axis. This is, of course, due to the input flow from X directed towards the device axis while the output flow Y leaves in the opposite axis side. This position of terminals, cf. Figure 7, is important for the design of oscillators, as is seen below.
For the generation of switched flow pulses (similar to those in the graphical presentation at the right-hand column of Figure 1 and also in Figure 2, both with idealised rectangular shape) the integrated amplifier pairs as shown in Figure 6 are used. They are almost completely similar to the integrated case in the bottom part of Figure 5, with single but important difference: present in Figure 6 (but absent in Figure 5) are two attachment walls on both sides of the jet flowpath. By a phenomenon known as the Coanda effect [18], the jet leaving the supply nozzle attaches to one of these walls. There it remains attached even if the input flow is decreased to zero. The version with the attachment walls is sometimes described as binary memory element. As a result of the Coanda effect, the jet deflection in the Figure 6 version is not proportional to the input flow (as is the case in the continuously operating amplifier examples seen in Figure 5). Instead, the jet is switched between the full deflection on one side alternating with full deflection on the other side. Because of the increasing importance of switched flow pulses in contemporary fluidics, the configuration presented in Figure 6 is the most often used amplifier version, not only in oscillators but also in various other applications. Schematic presentation of the commercially most widespread amplifiers —similar to the representation of a simple amplifier in Figure 3—is presented in Figure 7.

4. Oscillators and Their Feedback Loops

Even though it is sometimes not recognisable immediately, all oscillation generators have two essential components: an amplifier and a feedback loop, as shown in Figure 8. The loop is a simple return flow channel that transports a small proportion of the output fluid flow from the exit terminal Y to the input terminal X. The loop sometimes contains additional fluidic components like resistors or accumulation chambers, that serve the purpose of adjusting the return flow behaviour.
The idea of the feedback came to fluidics in a direct analogy to the much earlier developments in the no-moving-part electronics. The amplifiers for amplification of electronic signals were developed from the thermionic diode invented by Fleming [19] in 1904. Diodes were developed into a vacuum tube amplifier via the addition of the grid, the third terminal. The idea was patented by DeForest [20]. In principle, as seen in top of Figure 3, the roles of the three terminals in the vacuum tube amplifier were fully analogous to the terminals S, X, and Y of the fluidic amplifiers. It was with this vacuum tube amplifier that the final step to the oscillators by the addition of the feedback loop was made. It was invented by Armstrong [21] in 1913. It should be emphasised that apart from the generation and amplification of periodically oscillating flows, the feedback loop can perform several other useful tasks. As a matter of fact, the simple signal connection from Y to X, as it is shown (with the amplifier from Figure 4) in the example presented in Figure 9 would actually not produce the oscillation effect at all. The reason is this simplest case is positive feedback. It operates as schematically represented in Figure 10. Such behaviour may be quite useful for some other tasks but not for the role of the oscillators of interest here. The input signal in X would rapidly move the deflected jet towards its full deflection. After that, the conditions would remain stationary, with constant maximum output signal in the exit Y as long as there is a supply flow S.
The desirable feedback generation of pulsating oscillation, as seen in Figure 11, is obtained by two processes taking place in the feedback loop channel. The first one is inversion of the return flow by an invertor as schematically represented in Figure 11. It results in the negative type of the feedback. The second process is the need to secure a certain duration of the generated pulse. This is obtained by the time delay in the loop.
Apart of the oscillators, there is yet another important group of devices in fluidics. They are perhaps less known but certainly not of lesser importance. It is the family of pulse shapers. For correct operation, the pulses have to show distinct leading and trailing edges. Because of the usually complex frequency spectrum of the unsteady responses of the amplifier—as well as the various devices that may be connected into the feedback loop—the shapes of arriving pulses may be quite far from the ideal. The individual components of the signal spectrum travel at different speeds. Also the values of the amplifier gain may be different for different frequencies. In fact, some harmonic components, especially those of higher frequencies, may be completely filtered out. Moreover, the shapes of the individual pulses in a high-frequency pulse train may be deformed differently (due to varied phase transport effects).
To avoid the unpleasant consequences of these signal deformations, it is useful to run the flow pulses through the pulse shaper device for correction. The device may be based on the schematically represented system in Figure 12 (even though the actual realisation may be very much different). The desirable pulse correction may be obtained by the use of two parallel feedback loops. One of them, the outer positive loop, generates the properly shaped leading edges of the pulses. The other loop, the inner negative feedback loop with time delay, takes care of the trailing edges. Generated pulse is thus started by the flow in the positive feedback, the same as in Figure 10, but then comes the delayed more powerful negative feedback that stops the output flow. Its delay defines the pulse trailing edge. The result are pulses having all the same duration ΔtY determined by the properties of the time delay in the negative feedback, i.e., irrespective of the duration ΔtX of the input pulse that may come corrupted. As it is apparent, the pulse shapers have in principle very much in common with oscillators.

5. Flip-Flop Circuits

In the early era of electronics, with vacuum tube amplification technology the forefather of fluidics, an interesting pulse generating circuit was invented characterised by a pair of amplifiers arranged in anti-parallel. This circuit, of which a direct analogy was later made in wluidics, is particularly well suited for the generation and handling of the rectangular-shaped flow pulses. Its basic configuration is presented in general terms in Figure 13. Inventors were Abraham and Bloch in France, electronic engineers working during WWI on developments in radio transmission. Due to the applied rules of military secrets, their publication [22] had to be postponed until after the war, and in the meantime Eccless and Jordan in Britain obtained the patent on the same idea [23]. The inventors of [22] called the device “multi-vibrateur.” The meaning of this term is obvious in Fouriér analysis of the generated pulse. It spectrum results from generation of many (theoretically infinitely many) multiples of the harmonic multiples of the base frequency. Eccles and Jordan [23] called their circuit ”flip-flop”. Amplifiers of the pair are switched between their two extreme regimes, OPEN (large output Y) and CLOSED (Y = 0), as shown in the diagram at the bottom of right-hand side in Figure 13. By adjusting the parameters of the components in the circuit, it is possible to operate it in three alternative useful operational modes. In the bistable mode, the flows remain stable in either one of two regimes. It may be the regime with the steady flow in Y1 or the equally stable regime with steady flow in Y2. Othervise, the regime may be monostable with one of the output channels dominant so that to it the circuit always returns in the absence of control input. Finally, the self-excited oscillating version is described as astable.
The jet-deflection fluidic amplifier version shown above in Figure 6 operates as the “flip-flop” presented schematically in the Figure 13. It should be noted there that while the mutual blockage of the amplifiers in Figure 13 requests a crossing of the signal transfer channels connecting the amplifiers (which would cause manufacturing complication in what is the essentially a single-plane configuration), in the fluidic versions shown in Figure 14, with control nozzles on the opposed locations, no such spatial crossing of the signal channels is necessary. The inverting character of the negative feedback to get the oscillation is obtained by connecting the terminals Y with X located on the same side of the fluidic amplifier.
Let us start the description of the circuit in Figure 13 by assuming both amplifiers are initially in the OPEN state. At the output Y1 of Amplifier 1 a part of the flow from its OPEN flow output is removed and sent into the invertor. There it becomes of the CLOSED character, but this becomes active only after a certain delay. The signal is then sent to the input X2 of the other Amplifier 2 which it switches into the CLOSED state. This regime, with one amplifier OPEN and the other CLOSED takes some time because of the two delays. Then the CLOSED input X2 is amplified to the more powerful output level Y2. After another delay the amplified Y2 is delivered to the input X1 of the Amplifier 1, which becomes CLOSED. With no flow through Amplifier 1 the invertor becomes the OPEN and this input signal is delivered into the Amplifier 2. Again, this regime stays stationary for some time and this defines duration of one time in the generated pulses. Thus the two amplifiers alternate in OPEN and CLOSED mutually opposed states.
In fluidics, the idea of feedback loops to generate the oscillation in analogy to electric circuits was followed once the pure fluidic amplifiers became available. It was Warren [15] in 1962 who obtained a US patent on the subject of a fluidic oscillator with two mutually integrated fluidic amplifiers, i.e., with the configuration shown in Figure 6, characterized by the two negative feedback loop channels. Schematic representations of Warren’s oscillator with integrated fluidic amplifiers are here in the top of Figure 14. The two flowpaths in the configuration in Figure 6 necessitate, of course, using in the oscillator the two negative feedback loop channels. Today, this fluidic oscillator is the most popular member of the family of fluidic devices.

6. Flow Time Delay in Fluidic Oscillators

6.1. Delay by Fluid Flow along Channel Length

Typical geometry of an oscillator with integrated jet-deflection amplifier and the characteristic two feedback loops as invented by Warren [15] is presented here in Figure 15. Both flowpaths share the common deflected jet issuing from the single supply nozzle. There are two attachment walls, a pair of control nozzles, and also two collectors for capturing the jet and delivering it to the output terminals. That configuration is more complex than is strictly necessary for the oscillation task that this circuit performs. Popularity of the fluidic device in Figure 15 is due to the reliability with which the oscillation is started in response to an applied starting signal. This is the consequence of the bistable amplifier’s separate control of both the beginning and end (leading and trailing edge) of the generated oscillation pulse. The jet is thus reliably switched at exactly the time of the pulse edge.
Capable of generating the pulses in a more simple way, but exhibiting less satisfactory operational reliability, is the oscillator version with the single-flowpath amplifier an example of which is shown in Figure 16. Its is described as monostable because in the no-input-signal regime the jet always attaches to the single available Coanda-effect wall. The amplifier is supplied by a permanent fluid flow delivered into the input terminal X. Beginning of the attachment wall is located at the exit of the supply nozzle. The jet generated in this nozzle attaches to this wall. and leads it to the output terminal Y. At the downstream end of the wall, the captured flow is divided into two parts. While one part leaves to the output terminal Y, the rest enters the feedback channel which brings the fluid to the control nozzle, which is oriented perpendicularly to the supply nozzle axis. If there is a flow from the control nozzle, the Coanda effect cannot keep the jet attached to the attachment wall. The supplied flow separates from this wall and together with the control flow leaves to atmosphere through the vent terminal (at the upper part of the picture). Of course, with the resultant absence of the flow past the attachment wall, the flow through the output terminal Y stops. The switching of the flow into this regime is not immediate. It is delayed by the duration of the flow past the attachment wall. This delay defines the time between pulses.
The relative width of the generated pulses is characterised by their “duty cycle”, defined as the ratio of pulse ON duration to the total time of the oscillation period Δtp. In the oscillator shown in Figure 16, the duty cycle is constant, determined by the geometry of the device’s internal cavity.
In the bistable amplifier version with two feedback loops in Figure 15, it is possible to adjust the duty cycle value. This is done by separately adjusting the lengths of the two feedback channels. As seen in Figure 15, Figure 16 and Figure 17, the pulse widths and duty cycle are determined by three factors. It is the feedback loops’ lengths, the flow velocities in them, and also the (usually quite small) switching time of the jet in the amplifier. The most important parameter, propagation velocity in the loop, may be estimated by the relations in Figure 17 (adapted from reference [13]) and in the diagram Figure 18. as a function of available driving pressure difference. It may be noted that this propagation time delay in a simple channel is a typical example of an effect in which the analogy between fluidics and electric circuitry fails - because the electrons propagation in a conductor is extremely fast and delays have to be arranged differently. As a final note on the subject of feedback loops, the device shown in Figure 19 may be seen as a proposal for a pulse shaper based directly on the signal flows from Figure 12.

6.2. Achieving Higher Oscillation Frequencie

It should be mentioned that the classical hydraulic and pneumatic devices can actually also operate at quite high oscillation frequencies. The problem is not in achieving at such frequencies, but rather the dangerously high pressure levels needed for them. The high pressure force is necessary for moving or deforming the mechanical component. For a high natural frequency, this force must be much higher than the inertial forces. As the consequence, the operating conditions occupy in the diagram in Figure 18 the part on the right-hand side, at the high pressure levels. where they can approach dangerously high mechanical stressing.
One of the advantages of pure fluidics is that the devices, especially when working with gas, occupy the area of low pressure at left in the diagram Figure 18. It is thus possible without high stresses to design operating conditions of high velocities and high frequencies. Of course, in considering the high frequencies, there are other aspects to be taken into consideration. An important aspect is the overall size of the device. Very roughly, with present-day usual devices of overall sizes from 20 mm to 200 mm, the operating frequencies of oscillators according to Figure 15 with reasonably long feedback channels operate typically between f ≈ 50 Hz and f ≈ 200 Hz.
Somewhat higher frequencies, say ≈ 400 Hz, may be obtained with a different, resonator feedback [5,24] operating with compression and expansion waves traveling in a resonant cavity. The limiting factor with the standard design in Figure 15 are the reasonable lengths and turning angles of the channel flow. In typical methods of fluidic device manufacturing, the circuit components are distributed in a plane from which are removed those parts in the resultant cavities of which the fluid flows. This, of course, leads to is a problem with the “island” left free according to Figure 16 and Figure 19.
Very short feedback travel distances are achievable by removing the “island” altogether and relying on the more or less stationary vortices, as they are shown in Figure 20. With ≈ 20 mm overall size device cavities, oscillators based on this “stationary vortex” cavities were demonstrated to operate at ≈ 500 Hz.
Interesting yet little known are the high-frequency fluidic oscillators discussed in Reference [25], characterised by the single captive vortex in a cavity downstream from the supply nozzle exit, seen in Figure 21. This design was applied for use in applications requiring flow pulsations at frequencies of the order of kilohertz, such as in the generation of the submillimetre gas microbubbles in liquids [1]. As shown in the illustration example in Figure 21, the very short time delays associated there with switching the deflected jet between the two attachment walls were obtained with the stationary vortex rotating in a chamber with a narrow output exit. While not of really tiny size (cavity dimensions were measured in millimetres), the oscillators were demonstrated to operate reliably at a frequency as high as f ≈ 8230 Hz.

6.3. Low Frequency: Delay by Captive Vortex Spin-Up

Very opposite requests are sometimes also made - for pure fluidic oscillators operating at frequencies that are very low. It may be claimed that even for this purpose, the oscillator with a flow-time delay in long feedback loop channels as shown in Figure 15 may be applicable. The problem is in the resultant very large lengths of the feedback loop channels. These long channels cannot be made by the etching in the plane substrates together with the amplifier. Instead they are arranged from flexible tubing. The tube lengths according to Figure 15 and Figure 18 have to be of the order of 10–100 metres. This is not only inconvenient for stowing the tubes somewhere in the fluidic system, but also the long lengths cause too high friction losses. The power available at the end of such long tubes may not suffice for switching the deflected jet.
A new solution was demanded—and was found in the typically long duration processes associated with starting up the fluid rotation in a closed chamber. Characteristic times there may be up to the order of minutes, and yet the whole oscillator may be quite compact. An example of this application of the vortex spin-up delay is the pulse shaping device originally presented in [26]. It is shown here in the top part of Figure 22 consisting of two components separated by a gap. On the left side of the picture, there is the vortex chamber with a tangentially directed inlet and axially oriented exit tube in the chamber center. Opposite to this exit is collector, as usual with a diffuser (which is here of conical shape and not the planar seen in Figure 6). In the center of the drawing are shown two typical regimes, (a) and (b), with character of the flow in them indicated by the gray curved arrows. Into the tangential input terminal X come the flow pulses of various (quite large) widths (durations). It is requested that each of these input pulses is converted into a constant duration output pulse shown at the bottom of Figure 22. All the re-shaped output pulses delivered from the output Y are of the same duration. This requested conversion is demonstrated by comparison with the diagrams in Figure 23.
At the beginning of the conversion process, according to (a) in Figure 22, the input terminal X flow pulse arrives. There is no rotation inside the vortex chamber because it was eliminated by fluid friction. Compressive accumulation of the fluid in the chamber is negligible so that the fluid generates an axially oriented jet entering the collector at the more or less same flow rate as the instantaneous input flow in X. The jet inertia carries the fluid across the gap between from the chamber into the collector. From the initial zero flow rate in Y the output flow rapidly increases.
Gradually, however, because of the tangential orientation of the inlet X, the fluid inside the vortex chamber begins to rotate—at a progressively increasing speed. The fluid flow trough the chamber thus has to overcome the increasing centrifugal acceleration. The output from the vortex chamber exit ceases to increase, and the regime (a) changes to the regime (b) in Figure 22. In the gap, the centrifugal force pushes the fluid through the gap radially away. As a result, the flow captured in the collector decreases and finally the output pulse flow in Y stops. Although the input pulse continues to arrive, this is not reflected in the output. Whatever the length ΔtX of the input pulses is, in Y the output pulse duration ΔtY is short and always the same. Another use of this pulse shaper is demonstrated in Figure 24. The pulses indicate in the output Y the instants of sign change in the input signal.

6.4. Oscillator with Load-Switched Vortices

Essentially the same principle, the delay caused by gradually increasing rotation of a captive vortex, is also used in a low-frequency generator of periodic pulse trains [26,27], presented in Figure 25 and Figure 26. In contrast to the 3D spatial configuration shown in Figure 22, suitable for use in power fluidics, the oscillator in Figure 26 is of a planar configuration. This is advantageous from the point of view of contemporary small-scale manufacturing. There are two mutually similar vortex chambers, 1 and 2. They both have a tangentially oriented inlet and centrally positioned exit perpendicular to the illustration plane of Figure 26. The inlets are connected to exits of what is essentially a bistable Coanda-effect jet-deflection flow diverter. It is very much similar to bistable amplifiers, from which it differs by the absence of control terminals since it is switched by applying the load switching approach. This is explained in Figure 25. The diverter in this illustration is completely similar to that in Figure 26, but there are no vortex chambers. Their hydraulic resistance is replaced by the more general idea of fluidic loads: connection of devices generating a pressure drop. In the initial flow regime, the jet in the top picture part A of Figure 25 is shown attached to the upper attachment wall leading to the output 1. If the fluidic resistance (dissipance) of the load connected to the upper output 1 is small, there is only a minimal change. The Coanda effect is sufficiently strong for keeping the jet deflected to the upper output 1. If, however, the resistance is further increased, at some stage of this increase the Coanda effect fails. As shown in the bottom part B of Figure 25, the jet simply finds it easier to leave through the lower output 2. In Figure 25, this increased load is represented by the connected fluidic resistor, with smaller cross-section area available for the exit fluid from the diverter. In the oscillator shown in Figure 26, the increased load is due to the increased rotation speed inside the vortex chamber and the associated centrifugal force acting on the rotating fluid.

6.5. Very Low Frequency “Flip-Flop” Oscillato

Typical use of fluidic oscillators [29] is currently found in their increasing heat and/or mass transfer in various chemical and physical processes. The increase is usually the result of destroying the boundary layer, which behaves as an insulating stationary layer at a transfer surface. In the illustration Figure 26 is a schematic representation of the case of two parallel heat exchangers with flows fluidically pulsated [30] in a circuit containing a pair of vortex chambers. The flow, supplied through the supply inlet S, is divided into two parallel branches. It is pulsated so that a larger flow rate through the first exchanger is simultaneous with the smaller flow rate through the second exchanger, and vice versa. The negative feedback and delay effects necessary for the oscillator, Figure 13, are here provided by the tube connecting the terminals X1 and X2.
In the next pair of pictures (Figure 27 and Figure 28), the pressure distributions generating the feedback effect are explained. For easier explanation, the exchangers as well as vortex chambers are in these pictures replaced by schematically presented fluidic resistors R (i.e., local cross-section area decreases). The pressure drops across the restrictor are represented by the vertical lengths of the lines and arrows in Figure 28 and Figure 29.
In Figure 28 is presented the situation in the first half of the oscillation cycle, with a larger flow rate through the first branch (at left). This larger flow also means a larger pressure drop ΔPexchang1 across the first heat exchanger (in Figure 28 represented by the longer arrow). There is no rotation inside the vortex chamber 1 so that the fluid passes through it radially into its central exit. This results in a small pressure drop ΔPvortex ch.1. At this time the conditions in the second branch (at right) are different. There is a smaller flow rate through the second exchanger (represented in Figure 29 by the shorter vertical arrow), and the pressure drop ΔPexchang2 is larger because the fluid inside the second vortex chamber rotates. As a result, the pressure in X2 is larger than the pressure in X1. The fluid thus flows away from vortex chamber 2 into the vortex chamber 1. As it enters this chamber tangentially, the rotation there progressively increases. The large length of the tube connecting the terminals X1 and X2 delaying the rotation. Also the flow away from the second vortex chamber through its center also stops the rotation. When the rotation intensity in vortex chamber 1 reaches its limit value, the pressure drop across the chamber 1 increases so that flow in the tube connecting the terminals X1 and X2 reverses its direction. The flow field thus becomes as shown in Figure 29.

7. Conclusions

This paper explains the operating principles of no-moving-part fluidic oscillators, which are devices currently finding increased application in a number of interesting uses. The principles are in some cases analogous to the forerunner circuits of electronics—but quite often used are also configurations that differ substantially. In particular, the paper provides an explanation of why the nowadays universally used fluidic amplifiers are the configurations with two mutually integrated flowpaths. The other not obviously analogy are the fluidic “flip-flop” circuits for the extreme conditions of very high and very low frequencies. Present standard time delays, without which the feedback loops would not work, are based on duration of axial (lengthwise) flow in the loop channel. Paper presents also the little known and yet important new ideas of the time delays based on reaching a certain magnitude of rotation speed of a captive vortex.

Funding

Author’s work was supported by grant 17-08218S obtained from GAČR—the Grant Agency of the Czech Republic. He was also a recipient of institutional support RVO: 61388998.

Conflicts of Interest

The authors declare no conflict of interest.

References

  1. Rehman, F.; Medley, G.J.; Bandulasena, H.; Zimmerman, W.B. Fluidic oscillator-mediated microbubble generation to provide cost effective mass transfer and mixing efficiency to the wastewater treatment plants. Environ. Res. 2014, 37, 32–39. [Google Scholar] [CrossRef] [PubMed]
  2. Desai, P.D.; Hines, M.J.; Riaz, Y.; Zimmerman, W.B. Resonant pulsing frequency effect for much smaller bubble formation with fluidic oscillation. Energies 2018, 11, 2680. [Google Scholar] [CrossRef]
  3. Zimmerman, W.B.; Tesař, V.; Butler, S.; Bandulasena, H. Microbubble generation. Recent Pat. Eng. 2008, 2, 1–8. [Google Scholar] [CrossRef]
  4. Seifert, A.; Pack, L.G. Active control of separated flow on a wall–mounted hump at high Reynolds numbers. AIAA J. 2002, 40, 1363–1372. [Google Scholar] [CrossRef]
  5. Tesař, V.; Zhong, S.; Fayaz, R. New fluidic oscillator concept for flow separation control. AIAA J. 2013, 51, 397–405. [Google Scholar] [CrossRef]
  6. Raghu, S. Fluidic oscillators for flow control. Exp. Fluids 2013, 54, 1455. [Google Scholar] [CrossRef]
  7. Ten, J.S.; Povey, T. Self-excited fluidic oscillators for gas turbines cooling enhancement: Experimental and computational study. J. Thermophys. Heat Transf. 2018, 33, 536–547. [Google Scholar] [CrossRef]
  8. Tesař, V. Enhancing impinging-jet heat or mass transfer by fluidically generated flow pulsation. Chem. Eng. Res. Des. 2009, 87, 181–192. [Google Scholar] [CrossRef]
  9. Tesař, V. Fluidic control of molten metal flow. Acta Polytech. J. Adv. Eng. 2003, 43, 15. [Google Scholar]
  10. Mairhofer, J.; Roppert, K.; Ertl, P. Microfluidic systems for pathogen sensing: A Review. Sensors (Basel) 2009, 9, 4804–4823. [Google Scholar] [CrossRef] [PubMed]
  11. Tesař, V. Role of microfluidics in discovering new marketable substances—A Survey. In Proceedings of the 19th International Conference, Svratka, Czech Republic, 13–16 May 2013; p. 614. [Google Scholar]
  12. Tesař, V. Microfluidic Systems for Combinatorial Chemistry. In Encyclopedia of Microfluidics and Nanofluidics; Li, D., Ed.; Springer Science Business Media: Berlin, Germany, 2008; p. 1221. [Google Scholar]
  13. Tesař, V. Pressure-Driven Microfluidics; Artech House Publishers: Norwood, MA, USA, 2007. [Google Scholar]
  14. Zalmanzon, L.A. Method of Automatically Controlling Pneumatic or Hydraulic Elements of Instruments and Other Devices. U.S. Patent 3,295,543, December 1959. [Google Scholar]
  15. Warren, R.W. Negative Feedback Oscillator. U.S. Patent 3,158,166, August 1962. [Google Scholar]
  16. Tesař, V.; Peszyński, K. Pneumatic sensors based on colliding curved wall-jets. Sens. Actuators A Phys. 2015, 228, 82–94. [Google Scholar]
  17. Tesař, V. Microfluidic turn-down valve. J. Vis. 2002, 5, 301–307. [Google Scholar] [CrossRef]
  18. Coanda, H. Device for Deflecting a Stream of Elastic Fluid Projected into an Elastic Fluid. U.S. Patent 2,052,869, 1 September 1936. [Google Scholar]
  19. Fleming, J.A. Instrument for Converting Alternating Electric Currents into Continuous Currents. U.S. Patent 803,684, 19 April 1905. [Google Scholar]
  20. DeForest, L. Device for Amplifying Feeble Electrical Current. U.S. Patent 841,387, 25 October 1906. [Google Scholar]
  21. Armstrong, E. Wireless Receiving System. U.S. Patent 1,113,149, 18 December 1913. [Google Scholar]
  22. Abraham, H.; Bloch, E. Mesure en valeur absolue des périodes des oscillations électriques de haute fréquence. Ann. Phys. 1919, 9, 237–302. [Google Scholar] [CrossRef]
  23. Eccles, W.H.; Jordan, F.W. Improvements in Ionic Relais. Patent UK 148,582, 21 June 1918. [Google Scholar]
  24. Tesař, V. Fluidic Oscillator with Jet-Type Bistable Amplifier. Patent CZ 303,758, August 2011. [Google Scholar]
  25. Tesař, V. High-frequency fluidic oscillator. Sens. Actuators A Phys. 2015, 234, 158–167. [Google Scholar] [CrossRef]
  26. Tesař, V. Device for Adjusting Time Dependence of Fluid Flow. Patent CZ 202,898, January 1979. [Google Scholar]
  27. Tesař, V. Fluidic Oscillator. Patent CZ 306,064, December 2014. [Google Scholar]
  28. Tesař, V.; Smyk, E. Fluidic low-frequency oscillator with vortex spin-up time delay. Chem. Eng. Process. Process. Intensif. 2015, 90, 6–15. [Google Scholar] [CrossRef]
  29. Tesař, V. Taxonomic trees of fluidic oscillators. EPJ Web Conf. 2017, 143, 02128. [Google Scholar] [CrossRef] [Green Version]
  30. Tesař, V. Heat Exchanger with Fluidic Device for Transfer Intensification. Patent CZ 262,367, December 1986. [Google Scholar]
Figure 1. Fluid flows with periodicity. Left column: time dependence of harmonic oscillations. Right column: ideal rectangular pulses. Cases are named: (a) small modulation depth, (b) fully pulsed flow, (c) amplitude of oscillating component larger than mean flow, and (d) alternating flow.
Figure 1. Fluid flows with periodicity. Left column: time dependence of harmonic oscillations. Right column: ideal rectangular pulses. Cases are named: (a) small modulation depth, (b) fully pulsed flow, (c) amplitude of oscillating component larger than mean flow, and (d) alternating flow.
Energies 12 03071 g001
Figure 2. Examples of signal encoded in properties of rectangular flow pulses. (A) Pulse width modulation with a constant relative value of duty cycle ΔtON/ΔtOFF. (B) Signal encoded in the frequency of constant-width pulses.
Figure 2. Examples of signal encoded in properties of rectangular flow pulses. (A) Pulse width modulation with a constant relative value of duty cycle ΔtON/ΔtOFF. (B) Signal encoded in the frequency of constant-width pulses.
Energies 12 03071 g002
Figure 3. Schematic representation of a signal and power flows in a fluidic amplifier. Top: the simples amplifier with three terminals. Bottom: the diverter type amplifiers decrease the output flow rate by letting some fluid to flow away through the vent.
Figure 3. Schematic representation of a signal and power flows in a fluidic amplifier. Top: the simples amplifier with three terminals. Bottom: the diverter type amplifiers decrease the output flow rate by letting some fluid to flow away through the vent.
Energies 12 03071 g003
Figure 4. The principle of jet-deflection type fluidic amplifier. The fluid flow is accelerated in a nozzle (usually before its leaving closed cavities as a jet) and decelerated in a diffuser (usually downstream from the collector capturing the jet).
Figure 4. The principle of jet-deflection type fluidic amplifier. The fluid flow is accelerated in a nozzle (usually before its leaving closed cavities as a jet) and decelerated in a diffuser (usually downstream from the collector capturing the jet).
Energies 12 03071 g004
Figure 5. In generation of oscillatory flows it is often useful to have two amplifiers connected so that they form the anti-parallel pair. They are integrated (bottom) to form a single circuit component.
Figure 5. In generation of oscillatory flows it is often useful to have two amplifiers connected so that they form the anti-parallel pair. They are integrated (bottom) to form a single circuit component.
Energies 12 03071 g005
Figure 6. Typical present-day series—produced amplifier of the jet-deflection type. It is actually an integrated version of two amplifiers, like those shown in Figure 5—in addition to which, making it particularly suitable for the generation and amplification of flow pulses, are the Coanda-effect attachment walls. From [13].
Figure 6. Typical present-day series—produced amplifier of the jet-deflection type. It is actually an integrated version of two amplifiers, like those shown in Figure 5—in addition to which, making it particularly suitable for the generation and amplification of flow pulses, are the Coanda-effect attachment walls. From [13].
Energies 12 03071 g006
Figure 7. Schematic presentation—in a manner similar to the simple single-channel amplifier in Figure 3—of the typical amplifier shown in Figure 6.
Figure 7. Schematic presentation—in a manner similar to the simple single-channel amplifier in Figure 3—of the typical amplifier shown in Figure 6.
Energies 12 03071 g007
Figure 8. Schematic representation of flows in a fluidic general feedback loop: a part of the output flow Y is returned to the input X.
Figure 8. Schematic representation of flows in a fluidic general feedback loop: a part of the output flow Y is returned to the input X.
Energies 12 03071 g008
Figure 9. Positive feedback loop channel added to the simple amplifier from Figure 4.
Figure 9. Positive feedback loop channel added to the simple amplifier from Figure 4.
Energies 12 03071 g009
Figure 10. Use of the positive feedback: The output Y is kept in the ON state even after the input flow pulse X ceases to exist.
Figure 10. Use of the positive feedback: The output Y is kept in the ON state even after the input flow pulse X ceases to exist.
Energies 12 03071 g010
Figure 11. Use of the negative feedback: generation of the periodic pulse train.
Figure 11. Use of the negative feedback: generation of the periodic pulse train.
Energies 12 03071 g011
Figure 12. Pulse shaper—schematic representation of its internal flows. The duration ΔtY of the output pulse is dependent solely on the delay in the inner loop and independent of the input pulses.
Figure 12. Pulse shaper—schematic representation of its internal flows. The duration ΔtY of the output pulse is dependent solely on the delay in the inner loop and independent of the input pulses.
Energies 12 03071 g012
Figure 13. Schematic presentation of the “flip-flop” pair of amplifiers blocking one another. A typical present-day amplifier shown in Figure 6 is actually an integrated version of this pair.
Figure 13. Schematic presentation of the “flip-flop” pair of amplifiers blocking one another. A typical present-day amplifier shown in Figure 6 is actually an integrated version of this pair.
Energies 12 03071 g013
Figure 14. The two basic properties of the oscillator feedback in Figure 11 and Figure 12 are (a) the inversion—needed for the negative character of the feedback—and (b) a suitable delay time. Top: the inversion of the signal is through mutual connections of Y1 with X2. Bottom: the simplest time delay is obtained with signal propagation through large loop channel lengths.
Figure 14. The two basic properties of the oscillator feedback in Figure 11 and Figure 12 are (a) the inversion—needed for the negative character of the feedback—and (b) a suitable delay time. Top: the inversion of the signal is through mutual connections of Y1 with X2. Bottom: the simplest time delay is obtained with signal propagation through large loop channel lengths.
Energies 12 03071 g014
Figure 15. Typical example of oscillator with flow time delays according to Warren’s U.S. patent [15]. The frequency of generated oscillation depends on the lengths of negative feedback loops with the connecting channels between the control X and output Y terminals of a bistable jet-deflection type amplifier.
Figure 15. Typical example of oscillator with flow time delays according to Warren’s U.S. patent [15]. The frequency of generated oscillation depends on the lengths of negative feedback loops with the connecting channels between the control X and output Y terminals of a bistable jet-deflection type amplifier.
Energies 12 03071 g015
Figure 16. Simpler than the two-loop oscillator in Figure 15, this example version has a monostable amplifier and only one feedback loop. Experience shows such pulse generators to be less reliable (sometimes failing to oscillate, sometimes missing a pulse).
Figure 16. Simpler than the two-loop oscillator in Figure 15, this example version has a monostable amplifier and only one feedback loop. Experience shows such pulse generators to be less reliable (sometimes failing to oscillate, sometimes missing a pulse).
Energies 12 03071 g016
Figure 17. Typical dependence between pressure difference across the nozzle and the exit velocity in a planar fluidic device. The delays in the version in Figure 15 are inversely proportional to the flow velocity w, which, in turn, increases (here for simplicity neglecting friction losses) with the square root of the acting pressure difference ΔP. Adapted from [13].
Figure 17. Typical dependence between pressure difference across the nozzle and the exit velocity in a planar fluidic device. The delays in the version in Figure 15 are inversely proportional to the flow velocity w, which, in turn, increases (here for simplicity neglecting friction losses) with the square root of the acting pressure difference ΔP. Adapted from [13].
Energies 12 03071 g017
Figure 18. Pressure and velocities prevailing in a typical fluid flow channels applicable to generating the delay. Higher velocities than shown here might be generated but would result in high energy dissipation (friction and conversion into heat). Other limits are stresses in the device body that may endanger its life and reliability.
Figure 18. Pressure and velocities prevailing in a typical fluid flow channels applicable to generating the delay. Higher velocities than shown here might be generated but would result in high energy dissipation (friction and conversion into heat). Other limits are stresses in the device body that may endanger its life and reliability.
Energies 12 03071 g018
Figure 19. An example of pulse shaper with monostable amplifier and two mutually opposed time-delay feedback loops. (A) Schematic representation of the configuration with both positive and negative loops. (B) Planar pulse shaper cavity (of constant depth everywhere). Note the secondary feedback loop missing in Figure 15.
Figure 19. An example of pulse shaper with monostable amplifier and two mutually opposed time-delay feedback loops. (A) Schematic representation of the configuration with both positive and negative loops. (B) Planar pulse shaper cavity (of constant depth everywhere). Note the secondary feedback loop missing in Figure 15.
Energies 12 03071 g019
Figure 20. In an attempt at increasing the frequency of generated oscillation, the feedback loops were here reduced to the “islandless” spaces for stationary (“captive”) vortices. The feedback path is shortest, but without solid guidance by walls (which are here too far from the deflected jet flowpath), there is an opportunity for non-reliability. Small versions (millimetre size) of this oscillator type can reach a frequency range with the top limit at ≈ 500 Hz.
Figure 20. In an attempt at increasing the frequency of generated oscillation, the feedback loops were here reduced to the “islandless” spaces for stationary (“captive”) vortices. The feedback path is shortest, but without solid guidance by walls (which are here too far from the deflected jet flowpath), there is an opportunity for non-reliability. Small versions (millimetre size) of this oscillator type can reach a frequency range with the top limit at ≈ 500 Hz.
Energies 12 03071 g020
Figure 21. Very high frequency fluidic oscillator [25] with a single permanently rotating vortex kept captive in the pre-chamber. This amplifier, of not large size (nozzle exit b × h = 1.191 mm × 2 mm) oscillated at a frequency as high as 8.23 kHz. Both jet deflections are unstable: in the first half-cycle it Coanda attachment is eliminated by inflow from atmosphere through the control nozzle, while in the second half-cycle, it is opposed by rotation of the vortex.
Figure 21. Very high frequency fluidic oscillator [25] with a single permanently rotating vortex kept captive in the pre-chamber. This amplifier, of not large size (nozzle exit b × h = 1.191 mm × 2 mm) oscillated at a frequency as high as 8.23 kHz. Both jet deflections are unstable: in the first half-cycle it Coanda attachment is eliminated by inflow from atmosphere through the control nozzle, while in the second half-cycle, it is opposed by rotation of the vortex.
Energies 12 03071 g021
Figure 22. Pulse shaper [26] based on the vortex spin-up delay as shown in Figure 22. (a) Initially the inertia of non-rotating input flow jet carries it from the vortex chamber to the output terminal Y across the gap. (b) In the full rotation, the centrifugal force causes the fluid to escape radially such that the output flow in Y is zero.
Figure 22. Pulse shaper [26] based on the vortex spin-up delay as shown in Figure 22. (a) Initially the inertia of non-rotating input flow jet carries it from the vortex chamber to the output terminal Y across the gap. (b) In the full rotation, the centrifugal force causes the fluid to escape radially such that the output flow in Y is zero.
Energies 12 03071 g022
Figure 23. Pulse shaping using the device shown in Figure 20. Top: dependence on time X shows the input flow with variable pulse widths. Bottom: Y shows the generated short output pulses of constant width ΔtX. Appearance of the pulse in the output identifies the time instant.
Figure 23. Pulse shaping using the device shown in Figure 20. Top: dependence on time X shows the input flow with variable pulse widths. Bottom: Y shows the generated short output pulses of constant width ΔtX. Appearance of the pulse in the output identifies the time instant.
Energies 12 03071 g023
Figure 24. Another use of the pulse sharper from Figure 22. The output pulse generated in the output Y identifies the instants at which the increasing input flow in X crosses the zero.
Figure 24. Another use of the pulse sharper from Figure 22. The output pulse generated in the output Y identifies the instants at which the increasing input flow in X crosses the zero.
Energies 12 03071 g024
Figure 25. Oscillator [28,29] with a load-switched bistable diverter and two alternatively rotated vortex chambers, with all components in planar configuration.
Figure 25. Oscillator [28,29] with a load-switched bistable diverter and two alternatively rotated vortex chambers, with all components in planar configuration.
Energies 12 03071 g025
Figure 26. Switching the jet to the opposite attachment wall (from output 1 to output 2) by the load that makes the flow into the output 1 more difficult. Adapted from Reference [27].
Figure 26. Switching the jet to the opposite attachment wall (from output 1 to output 2) by the load that makes the flow into the output 1 more difficult. Adapted from Reference [27].
Energies 12 03071 g026
Figure 27. Oscillator based on the “flip-flop” configuration. Agitation by alternating fast and slow flows in the heat exchangers transport processes according to Reference [29].
Figure 27. Oscillator based on the “flip-flop” configuration. Agitation by alternating fast and slow flows in the heat exchangers transport processes according to Reference [29].
Energies 12 03071 g027
Figure 28. Explanation of generated delayed fluid flow generating rotation in the vortex chamber 1. For simplicity of explanation the exchanges as well as vortex chambers are replaced by fluidic resistors R.
Figure 28. Explanation of generated delayed fluid flow generating rotation in the vortex chamber 1. For simplicity of explanation the exchanges as well as vortex chambers are replaced by fluidic resistors R.
Energies 12 03071 g028
Figure 29. During the second half of the oscillation cycle, the direction of the control flow is reversed.
Figure 29. During the second half of the oscillation cycle, the direction of the control flow is reversed.
Energies 12 03071 g029

Share and Cite

MDPI and ACS Style

Tesař, V. Time-Delay Circuits for Fluidic Oscillators and Pulse Shapers. Energies 2019, 12, 3071. https://doi.org/10.3390/en12163071

AMA Style

Tesař V. Time-Delay Circuits for Fluidic Oscillators and Pulse Shapers. Energies. 2019; 12(16):3071. https://doi.org/10.3390/en12163071

Chicago/Turabian Style

Tesař, Václav. 2019. "Time-Delay Circuits for Fluidic Oscillators and Pulse Shapers" Energies 12, no. 16: 3071. https://doi.org/10.3390/en12163071

Note that from the first issue of 2016, this journal uses article numbers instead of page numbers. See further details here.

Article Metrics

Back to TopTop