Paper The following article is Open access

Heat transfer at the stagnation point of the impinging laminar jet

, and

Published under licence by IOP Publishing Ltd
, , Citation V Lemanov et al 2020 J. Phys.: Conf. Ser. 1677 012018 DOI 10.1088/1742-6596/1677/1/012018

1742-6596/1677/1/012018

Abstract

Heat transfer of an impinging axisymmetric jet at low Reynolds numbers (Re = 250-5000) at the obstacle stagnation point was studied experimentally. An air jet from a long tube was flowing onto a flat heated plate at a constant wall temperature. The distance from the jet beginning to the obstacle was h/d = 20. A connection of thermal parameters (averaged and pulsating) at the stagnation point for the flow at the initial cross-section of the jet was established. For the laminar flow, an increase in heat transfer of more than 200% was observed in the jet in comparison with the turbulent flow. Comparison of the obtained data on heat transfer revealed a significant discrepancy with the well-known correlation formula for impinging jets.

Export citation and abstract BibTeX RIS

Content from this work may be used under the terms of the Creative Commons Attribution 3.0 licence. Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI.

Please wait… references are loading.
10.1088/1742-6596/1677/1/012018