Počet záznamů: 1  

Endoscopic Imaging Using a Multimode Optical Fibre Calibrated with Multiple Internal References

  1. 1.
    SYSNO ASEP0552078
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevEndoscopic Imaging Using a Multimode Optical Fibre Calibrated with Multiple Internal References
    Tvůrce(i) Jákl, Petr (UPT-D) RID, ORCID, SAI
    Šiler, Martin (UPT-D) RID, ORCID, SAI
    Ježek, Jan (UPT-D) RID, ORCID, SAI
    Cifuentes, Angel S. (UPT-D) RID, SAI, ORCID
    Traegaardh, Johanna (UPT-D) RID, ORCID, SAI
    Zemánek, Pavel (UPT-D) RID, SAI, ORCID
    Čižmár, Tomáš (UPT-D) RID, ORCID, SAI
    Číslo článku37
    Zdroj.dok.Photonics. - : MDPI
    Roč. 9, č. 1 (2022)
    Poč.str.10 s.
    Forma vydáníOnline - E
    Jazyk dok.eng - angličtina
    Země vyd.CH - Švýcarsko
    Klíč. slovafibre endoscopy ; spatial light modulator ; transmission matrix
    Vědní obor RIVBH - Optika, masery a lasery
    Obor OECDOptics (including laser optics and quantum optics)
    CEPEF15_003/0000476 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    LO1212 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    ED0017/01/01 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    Způsob publikováníOpen access
    Institucionální podporaUPT-D - RVO:68081731
    UT WOS000759106500001
    EID SCOPUS85123507712
    DOI10.3390/photonics9010037
    AnotaceThe interferometric acquisition of the transmission matrix (TM) of a multimode optical fibre (MMF), which is at the heart of multimode fibre-based endoscopic imaging methods, requires using a reference beam. Attempts to use an internal reference, that is to provide the reference in a common pathway geometry through the MMF itself, lead to a speckled reference intensity and consequential occurrence of “blind spots” - locations where insufficient optical power in the reference wave inflicts strong measurement errors. Here we show that combining a relatively small number of TMs, which are measured using different internal references, facilitates a complete elimination of blind spots, and thereby a significant enhancement of the imaging quality.
    PracovištěÚstav přístrojové techniky
    KontaktMartina Šillerová, sillerova@ISIBrno.Cz, Tel.: 541 514 178
    Rok sběru2023
    Elektronická adresahttps://www.mdpi.com/2304-6732/9/1/37
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.