Počet záznamů: 1  

Wind-stilling in the light of wind speed measurements: the Czech experience

  1. 1.
    SYSNO ASEP0483909
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevWind-stilling in the light of wind speed measurements: the Czech experience
    Tvůrce(i) Brázdil, Rudolf (UEK-B) RID, SAI, ORCID
    Valík, A. (CZ)
    Zahradníček, Pavel (UEK-B) RID, SAI
    Řezníčková, Ladislava (UEK-B) RID, SAI
    Tolasz, R. (CZ)
    Možný, M. (CZ)
    Zdroj.dok.Climate Research - ISSN 0936-577X
    Roč. 74, č. 2 (2018), s. 131-143
    Poč.str.13 s.
    Jazyk dok.eng - angličtina
    Země vyd.DE - Německo
    Klíč. slovauniversal anemograph ; vaisala wind-speed sensors ; wind speed ; homogenisation ; wind stilling ; Czech Republic
    Vědní obor RIVDG - Vědy o atmosféře, meteorologie
    Obor OECDMeteorology and atmospheric sciences
    CEPLO1415 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    GA15-11805S GA ČR - Grantová agentura ČR
    Institucionální podporaUEK-B - RVO:86652079
    UT WOS000418809900004
    EID SCOPUS85040571877
    DOI10.3354/cr01492
    AnotaceChanges of instruments often give rise to significant break-points in wind-speed series. This is particularly applicable when measurements are automated, a process that started in the Czech Republic in the mid-1990s, when standard universal anemographs were progressively replaced by the Vaisala WAA251 sensor (cup anemometer) and the WS425 sensor (ultrasonic). Parallel wind speed measurements, by universal anemographs and Vaisala sensors, at the Doksany (2000-2016) and Kocelovice (2000-2016) stations enabled differences in the 2 types of measurement to be analysed. Vaisala sensors measure, on average, higher wind-speeds than universal anemographs, particularly in calm situations and at low wind speeds. The differences between the 2 types of instrument do not depend on wind direction. Linear trends of homogenised daily mean wind-speed series from only a universal anemograph or combined from universal anemograph and Vaisala sensors generally exhibit no important differences in their significance or values. This could indicate that observed decreasing trends in mean daily wind-speeds ('stilling') cannot be attributed to changes of wind-speed measurements to automated devices, with respect to only 2 stations being investigated, this is biased by high uncertainty. In contrast, important differences in the 2 types of measurement, both in linear trends and their significance, appear for series of 3 daily readings (07: 00, 14: 00 and 21: 00 h LMT).
    PracovištěÚstav výzkumu globální změny
    KontaktNikola Šviková, svikova.n@czechglobe.cz, Tel.: 511 192 268
    Rok sběru2019
Počet záznamů: 1  