Počet záznamů: 1  

Effects of Continuous and Pulsating Water Jet on CNT/Concrete Composite

  1. 1.
    SYSNO ASEP0482312
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevEffects of Continuous and Pulsating Water Jet on CNT/Concrete Composite
    Tvůrce(i) Foldyna, Vladimír (UGN-S)
    Foldyna, Josef (UGN-S) RID, ORCID
    Klichová, Dagmar (UGN-S) RID, ORCID
    Klich, Jiří (UGN-S) RID, ORCID
    Hlaváček, Petr (UGN-S) RID, ORCID
    Bodnárová, L. (CZ)
    Jarolím, T. (CZ)
    Mamulová Kutláková, K. (CZ)
    Celkový počet autorů8
    Zdroj.dok.Strojniski Vestnik-Journal of Mechanical Engineering - ISSN 0039-2480
    Roč. 63, č. 10 (2017), s. 583-589
    Poč.str.7 s.
    Forma vydáníOnline - E
    Jazyk dok.eng - angličtina
    Země vyd.HR - Chorvatsko
    Klíč. slovapulsating and continuous water jet ; CNT/concrete composite ; material removal
    Vědní obor RIVJQ - Strojní zařízení a nástroje
    Obor OECDCivil engineering
    CEPLO1406 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    ED2.1.00/03.0082 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    GA15-23219S GA ČR - Grantová agentura ČR
    Institucionální podporaUGN-S - RVO:68145535
    UT WOS000413204700005
    DOI10.5545/sv-jme.2017.4357
    AnotaceThis paper presents first results of the study of the resistance of carbon nanotube concrete composite (CNT/concrete composite) to the action of continuous and pulsating water jets. The experiments oriented at the determination of erosion effects of pulsating and continuous water jets impinging the surface of reference (concrete) and CNT/concrete composite samples were performed. Tested samples were characterized by X-ray powder diffraction and scanning electron microscope. Samples were exposed to pulsating and continuous water jets at various operating parameters. Erosion effects of pulsating and continuous jets were evaluated in terms of material removal rate. The possible influence of addition of CNTs to the concrete on its resistance to the action of continuous and pulsating water jets is discussed in the paper. The experiments proved that CNT/concrete composite exhibits higher resistance than reference concrete to the action of both pulsating and continuous water jet under the given testing conditions.
    PracovištěÚstav geoniky
    KontaktLucie Gurková, lucie.gurkova@ugn.cas.cz, Tel.: 596 979 354
    Rok sběru2018
    Elektronická adresahttp://ojs.sv-jme.eu/index.php/sv-jme/article/view/sv-jme.2017.4357
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.