Počet záznamů: 1
Fast infrared thermography on the COMPASS tokamak.
- 1.
SYSNO ASEP 0481820 Druh ASEP J - Článek v odborném periodiku Zařazení RIV J - Článek v odborném periodiku Poddruh J Článek ve WOS Název Fast infrared thermography on the COMPASS tokamak. Tvůrce(i) Vondráček, Petr (UFP-V) RID, ORCID
Gauthier, C. (FR)
Ficker, Ondřej (UFP-V) ORCID
Hron, Martin (UFP-V) RID, ORCID
Imríšek, Martin (UFP-V) RID
Pánek, Radomír (UFP-V) RIDZdroj.dok. Fusion Engineering and Design. - : Elsevier - ISSN 0920-3796
Roč. 123, November (2017), s. 764-767Poč.str. 4 s. Forma vydání Tištěná - P Akce SOFT 2016: Symposium on Fusion Technology /29./ Datum konání 05.09.2016 - 09.09.2016 Místo konání Prague Země CZ - Česká republika Typ akce WRD Jazyk dok. eng - angličtina Země vyd. CH - Švýcarsko Klíč. slova Infrared thermography ; Heat flux decay length ; Runaway electrons ; Sawtooth Vědní obor RIV JF - Jaderná energetika Obor OECD Nuclear related engineering CEP 8D15001 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy LM2015045 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy GA15-10723S GA ČR - Grantová agentura ČR Institucionální podpora UFP-V - RVO:61389021 UT WOS 000418992000159 EID SCOPUS 85019160626 DOI 10.1016/j.fusengdes.2017.05.004 Anotace A new fast infrared camera was purchased on the COMPASS tokamak recently. It is equipped with a medium wavelength infrared (3-5 mm) InSb detector and is capable of reaching framerate up to 1.9 kHz in full frame acquisition mode (320 x 256 px.) and up to 90 kHz in sub-windowed mode (64 x 4 px.).
First experimental measurements of plasma heat flux to inner and outer wall limiters of the COMPASS tokamak using the new camera are presented. Time evolution of parallel heat flux during sawtooth instability is studied showing strong modulation of the heat flux absolute value whilst keeping constant its radial decay length. Fast modulation of outboard midplane limiter heat loading due to runaway electrons is also presented.
The camera will be part of a new fast divertor thermographic system with exceptional spatial resolution (similar to 0.6-1.3 mm/px. on the target plane, 0.04-0.14 mmipx. mapped to the outer midplane) with a possibility of measurements of radial profiles on the divertor with 320 x 4 px. with temporal resolution better than 20 mu s. A design of the foreseen optical divertor system is described together with a design of a special divertor graphite tile used for the IR thermography, that will allow in-situ surface emissivity calibration.Pracoviště Ústav fyziky plazmatu Kontakt Vladimíra Kebza, kebza@ipp.cas.cz, Tel.: 266 052 975 Rok sběru 2018
Počet záznamů: 1