Počet záznamů: 1  

Acoustic emission for interlaminar toughness testing of CFRP: Evaluation of the crack growth due to burst analysis

  1. 1.
    SYSNO ASEP0481723
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevAcoustic emission for interlaminar toughness testing of CFRP: Evaluation of the crack growth due to burst analysis
    Tvůrce(i) Lissek, F. (DE)
    Haegerb, A. (DE)
    Knoblauch, V. (DE)
    Hloch, Sergej (UGN-S) RID, SAI, ORCID
    Pude, F. (DE)
    Kaufeld, M. (DE)
    Celkový počet autorů6
    Zdroj.dok.Composites Part B-Engineering. - : Elsevier - ISSN 1359-8368
    Roč. 136, č. 1 (2018), s. 55-62
    Poč.str.8 s.
    Forma vydáníTištěná - P
    Jazyk dok.eng - angličtina
    Země vyd.GB - Velká Británie
    Klíč. slovaDCB ; interlaminar toughness testing ; acoustic emission ; CFRP ; burst analysis
    Vědní obor RIVJQ - Strojní zařízení a nástroje
    Obor OECDMaterials engineering
    Institucionální podporaUGN-S - RVO:68145535
    UT WOS000425077600007
    EID SCOPUS85032200414
    DOI10.1016/j.compositesb.2017.10.012
    AnotaceThe paper deals with interlaminar fracture toughness testing of three different types of specimens from unidirectional
    aerospace laminate M21/T800S (autoclaved and hot pressed) and the woven fabric ECG Carbon 12k
    with respect to the ASTM Standard D5582. Simultaneously the materials were monitored by acoustic emission to
    evaluate the results via burst analysis. CFRP-specimens were mounted in a CNC-machining center by a chopper
    wire. The lower wire was fixed at a load cell (KISTLER 9257 B) to measure the force development. Standard
    specification the movement speed in z-direction was set to 5 mm/min. The acoustic emission sensor iMPact XS
    with accuracy is±5% with a reference sensitivity of>1200 pC/N was fixed on the DCB-specimens with a twosided
    adhesive tape with thickness of 0,5 mm. The sensor iMPact XS has a frequency range from 1 mHz up to
    1 MHz limited to a maximum of 500 kHz. It has been found that the material properties correlate well with the
    results of the acoustic emission analysis. The burst rate reflects the manufacturing processes as it is influenced
    directly by the fibre bridging which occurs particularly for autoclaved composites. In contrast, the burst energy
    is not affected by the manufacturing process. It is only depending from the matrix properties.