Počet záznamů: 1
A study of the behaviour of copper in different types of silicate glasses implanted with Cu+ and O+ ions
- 1.
SYSNO ASEP 0479629 Druh ASEP J - Článek v odborném periodiku Zařazení RIV J - Článek v odborném periodiku Poddruh J Článek ve WOS Název A study of the behaviour of copper in different types of silicate glasses implanted with Cu+ and O+ ions Tvůrce(i) Švecová, B. (CZ)
Vařák, P. (CZ)
Vytykačová, S. (CZ)
Nekvindová, P. (CZ)
Macková, Anna (UJF-V) RID, ORCID, SAI
Malinský, Petr (UJF-V) RID, ORCID, SAI
Bottger, R. (DE)Celkový počet autorů 7 Zdroj.dok. Nuclear Instruments & Methods in Physics Research Section B. - : Elsevier - ISSN 0168-583X
Roč. 406, SEP (2017), s. 193-198Poč.str. 6 s. Forma vydání Tištěná - P Jazyk dok. eng - angličtina Země vyd. NL - Nizozemsko Klíč. slova silicate glasses ; ion implantation ; copper Vědní obor RIV BG - Jaderná, atomová a mol. fyzika, urychlovače Obor OECD Nuclear physics CEP LM2015056 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy GA15-01602S GA ČR - Grantová agentura ČR Institucionální podpora UJF-V - RVO:61389005 UT WOS 000409152800041 EID SCOPUS 85017385312 DOI 10.1016/j.nimb.2017.03.042 Anotace Glasses containing copper are promising photonic materials for lasing devices and all-optical components. It has already been shown that the oxidation state of the implants depends on many factors. This paper is going to report on one of them, i.e. the influence of the composition of a silicate glass matrix on the behaviour of the implanted Cu ions before and after a subsequent implantation of oxygen ions. Three types of silicate glasses having a different extent of cross-linking were implanted with copper ions with an energy of 330 keV and a fluence 1 x 10(16) ions cm(-2). Then the glasses were implanted with oxygen ions with an energy of 110 key into the same depth as the already implanted Cu ions. The concentratiori depth profiles of Cu in the glasses were studied by Rutherford Bacicscattering Spectrometry. After the implantation, the samples were characterised by optical absorption and photoluminescence spectroscopy. The samples were annealed in ambient atmosphere for 1 h at 600 degrees C, which is near the transformation temperature of those glasses. The effect of annealing on the distribution of the implants and on the absorption and emission spectra of the as-implanted glasses will be discussed as well. Pracoviště Ústav jaderné fyziky Kontakt Markéta Sommerová, sommerova@ujf.cas.cz, Tel.: 266 173 228 Rok sběru 2018
Počet záznamů: 1