Počet záznamů: 1  

Comparison of Hexane Vapour Permeation in Two Different Polymeric Membranes via an Innovative In-Line FID Detection Method.

  1. 1.
    SYSNO ASEP0475966
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevComparison of Hexane Vapour Permeation in Two Different Polymeric Membranes via an Innovative In-Line FID Detection Method.
    Tvůrce(i) Petrusová, Zuzana (UCHP-M) RID, ORCID, SAI
    Morávková, Lenka (UCHP-M) RID, SAI
    Vejražka, Jiří (UCHP-M) RID, ORCID, SAI
    Vajglová, Zuzana (UCHP-M) RID, ORCID, SAI
    Jansen, J.C. (IT)
    Izák, Pavel (UCHP-M) RID, ORCID, SAI
    Zdroj.dok.Chemical and Biochemical Engineering Quarterly - ISSN 0352-9568
    Roč. 31, č. 2 (2017), s. 145-160
    Poč.str.16 s.
    AkceInternational Congress of Chemical and Process Engineering CHISA 2016 /22./
    Datum konání27.08.2016 - 31.08.2016
    Místo konáníPrague
    ZeměCZ - Česká republika
    Typ akceWRD
    Jazyk dok.eng - angličtina
    Země vyd.HR - Chorvatsko
    Klíč. slovagas/vapour separation ; low-density polyethylene ; thin-film-composite membrane
    Vědní obor RIVCI - Průmyslová chemie a chemické inženýrství
    Obor OECDChemical process engineering
    CEPLD14094 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    Způsob publikováníOpen access
    Institucionální podporaUCHP-M - RVO:67985858
    UT WOS000405761200004
    EID SCOPUS85023605038
    DOI10.15255/CABEQ.2016.1017
    AnotaceThis manuscript presents a novel method for the analysis of vapour permeation through polymeric membranes based on in-line analysis of the permeate with an FID detector. The hexane vapour permeation was studied for two commercially available membranes, namely low-density polyethylene (LDPE) and thin-film-composite polyamide (PA) membrane. The hexane permeation was studied at temperatures of 25–45 °C, hexane vapour activity in the range of 0.2–0.8 and trans-membrane pressures of 5–50 kPa. Two fundamentally different membranes were chosen to demonstrate the potential and sensitivity of the permeation apparatus. Upon increasing the temperature from 25 to 45 °C, the flux in LDPE was found to increase almost fourfold over the whole activity range. The nonlinear increase of the flux with activity indicates plasticization of the polymer by hexane. Contrarily, the flux in the PA membrane increases almost linearly with activity, with only a minor upward curvature. Since the PA is far away from any phase transition, it is less temperature-dependent than LDPE. The activation energy for permeation demonstrates that the temperature dependence in the LDPE membrane is dominated by changes in diffusion, whereas it is dominated by changes in solubility in the PA membrane.
    PracovištěÚstav chemických procesů
    KontaktEva Jirsová, jirsova@icpf.cas.cz, Tel.: 220 390 227
    Rok sběru2022
    Elektronická adresahttp://silverstripe.fkit.hr/cabeq/assets/Uploads/03-2-2017.pdf
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.