Počet záznamů: 1  

Catalyst-free „click” functionalization of polymer brushes preserves antifouling properties enabling detection in blood plasma

  1. 1.
    SYSNO ASEP0474248
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevCatalyst-free „click” functionalization of polymer brushes preserves antifouling properties enabling detection in blood plasma
    Tvůrce(i) Parrillo, Viviana (UMCH-V)
    de los Santos Pereira, Andres (UMCH-V) RID, ORCID
    Riedel, Tomáš (UMCH-V) RID, ORCID
    Rodriguez-Emmenegger, C. (DE)
    Zdroj.dok.Analytica Chimica Acta. - : Elsevier - ISSN 0003-2670
    Roč. 971, 8 June (2017), s. 78-87
    Poč.str.10 s.
    Jazyk dok.eng - angličtina
    Země vyd.NL - Nizozemsko
    Klíč. slovaaffinity optical biosensors ; blood plasma ; fouling
    Vědní obor RIVCD - Makromolekulární chemie
    Obor OECDPolymer science
    CEPGJ15-09368Y GA ČR - Grantová agentura ČR
    LQ1604 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    ED1.1.00/02.0109 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    Institucionální podporaUMCH-V - RVO:61389013
    UT WOS000400588500009
    EID SCOPUS85017459034
    DOI10.1016/j.aca.2017.03.007
    AnotaceProgress in biosensors for clinical detection critically relies on modifications of the transducer surface to prevent non-specific adsorption from matrix components (i.e. antifouling) while supporting biomolecular recognition elements to capture the analyte. Such combination of properties presents a significant challenge. Hierarchically structured polymer brushes comprising an antifouling polymer bottom block and a functionalizable top block are proposed as a promising strategy to achieve this goal. We employed the catalyst-free strain-promoted alkyne–azide cycloaddition (SPAAC) „click” reaction to biofunctionalize antifouling polymer brushes without impairing their resistance to fouling. The functionalization was performed on the side chains along the top polymer block or only on the end-groups of the polymer brush. The immobilized amounts of bioreceptors (streptavidin followed by biotin-conjugated proteins) and the resistance to fouling from blood plasma of the surfaces obtained were evaluated via surface plasmon resonance. The end group functionalization approach resulted in very low immobilization of bioreceptor. On the other hand, the side group modification of a top polymer block led to immobilization of 83% of a monolayer of streptavidin. Following binding of a biotin-conjugated antibody (66 ng cm-2) the functionalized layer was able to reduce the fouling from undiluted human blood plasma by 89% in comparison with bare gold. Finally, the functionalized hierarchical polymer brushes were applied to the label-free detection of a model analyte in diluted human blood plasma, highlighting the potential for translation to medical applications.
    PracovištěÚstav makromolekulární chemie
    KontaktEva Čechová, cechova@imc.cas.cz ; Tel.: 296 809 358
    Rok sběru2018
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.