Počet záznamů: 1  

Growth and differentiation of human osteoblast-like cells on TI-6AL-4V alloy modified with anodization

  1. 1.
    SYSNO ASEP0470315
    Druh ASEPC - Konferenční příspěvek (mezinárodní konf.)
    Zařazení RIVD - Článek ve sborníku
    NázevGrowth and differentiation of human osteoblast-like cells on TI-6AL-4V alloy modified with anodization
    Tvůrce(i) Doubková, Martina (FGU-C) ORCID, RID
    Bačáková, Lucie (FGU-C) RID, ORCID
    Pařízek, Martin (FGU-C) RID
    Vandrovcová, Marta (FGU-C) RID, ORCID
    Musílková, Jana (FGU-C) RID, ORCID
    Lisá, Věra (FGU-C)
    Gabor, R. (CZ)
    Marvan, J. (CZ)
    Zdroj.dok.NANOCON 2015: 7th International Conference on Nanomaterials - Research and Application, Conference Proceedings. - Ostrava : TANGER, spol. s r.o., 2015 - ISBN 978-80-87294-63-5
    Rozsah strans. 460-465
    Poč.str.6 s.
    Forma vydáníTištěná - P
    AkceNANOCON 2015. International Conference /7./
    Datum konání14.10.2015 - 16.10.2015
    Místo konáníBrno
    ZeměCZ - Česká republika
    Typ akceEUR
    Jazyk dok.eng - angličtina
    Země vyd.CZ - Česká republika
    Klíč. slovaTi6-Al4-V ; SAOS-2 cells ; anodization ; bone implants ; collagen I ; mineralization
    Vědní obor RIVEI - Biotechnologie a bionika
    CEPTA04011214 GA TA ČR - Technologická agentura ČR
    NV15-32497A GA MZd - Ministerstvo zdravotnictví
    Institucionální podporaFGU-C - RVO:67985823
    UT WOS000374708800081
    EID SCOPUS84962822286
    AnotaceTitanium and its alloys are widely used as hard tissue implants for their high biocompatibility and suitable physical properties. Along with other surface treatment methods, anodization technique is known to enhance osseointegration. The aim of this study is to evaluate the adhesion, growth and osteogenic differentiation of human osteoblast-like SAOS-2 cells on Ti-6Al-4V samples anodized in electrolytes composed of a stable volume of KOH (336.48 g/l) and variable volumes of liquid glass (124.47 g/l, 84,12 g/l and 37.38 g/l; samples s5, s6 and s7, respectively). Non-anodized Ti-6Al-4V samples, cell culture polystyrene (PS) and microscopic glass coverslips served as control materials. On days 2 and 4 after seeding, the cell number did not differ significantly among the tested samples. However, on day 7, the cell number on s6 samples reached the lowest values, which could be attributed to a non-homogeneous TiO2 film on s6 samples formed during anodization. Nevertheless, the osteogenic differentiation, estimated by the intensity of fluorescence of collagen I in cells grown in a differentiation medium, was the highest on s6 samples. On s5 samples, coated with homogeneous TiO2 films, both cell numbers and intensity of fluorescence of collagen I was relatively high. The bone matrix mineralization, evaluated by Alizarin Red staining, was the highest on s5 samples in standard culture medium, and similar on all tested samples in differentiation medium. Thus, the surface modification of s5 samples could be considered the most suitable for application in bone implants.
    PracovištěFyziologický ústav
    KontaktLucie Trajhanová, lucie.trajhanova@fgu.cas.cz, Tel.: 241 062 400
    Rok sběru2017
Počet záznamů: 1  