Počet záznamů: 1  

Numerical Simulation of Fatigue Crack Growth in Hip Implants

  1. 1.
    SYSNO ASEP0461706
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevNumerical Simulation of Fatigue Crack Growth in Hip Implants
    Tvůrce(i) Colic, K. (RS)
    Sedmak, A. (RS)
    Grbovic, A. (RS)
    Burzić, M. (RS)
    Hloch, Sergej (UGN-S) RID, SAI, ORCID
    Sedmak, S. (HR)
    Celkový počet autorů6
    Zdroj.dok.Procedia Engineering. - Amsterdam : Elsevier BV
    Roč. 149, č. 149 (2016), s. 229-235
    Poč.str.7 s.
    Forma vydáníOnline - E
    AkceInternational Conference on Manufacturing Engineering and Materials, ICMEM 2016
    Datum konání06.06.2016 - 10.06.2016
    Místo konáníNový Smokovec
    ZeměSK - Slovensko
    Typ akceEUR
    Jazyk dok.eng - angličtina
    Země vyd.NL - Nizozemsko
    Klíč. slovabiomedical application design ; extended finite element method (XFEM) ; Ti-6Al-4V alloy ; stress intensity factor (SIF) ; fatigue crack growth
    Vědní obor RIVJQ - Strojní zařízení a nástroje
    CEPED2.1.00/03.0082 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    LO1406 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    Institucionální podporaUGN-S - RVO:68145535
    UT WOS000386946500030
    EID SCOPUS84980009995
    DOI10.1016/j.proeng.2016.06.661
    AnotaceIn this paper numerical analysis of hip replacement implant behaviour from a fracture mechanics perspective is presented. It is necessary to understand the fatigue crack initiation and propagation characteristics in order to prevent catastrophic failure of the implant. For the simulation of crack propagation extended finite element method (XFEM) was used, as being one of the most advanced modeling techniques for this type of problem. Short theoretical background information on the XFEM is provided, as well as the representation of crack and the stress intensity factors computation. For chosen titanium alloy hip implants numerical modeling and analysis were done in ABAQUS software. It is shown that is possible to assume hip implant mechanical behaviour to the existence of defects such as cracks by application of numerical simulation crack behaviour. The numerical results illustrate that XFEM is efficient for the simulation of crack propagation in complicated biomedical structures, without the need to re-mesh during the propagation if the finite element mesh is well defined.
    PracovištěÚstav geoniky
    KontaktLucie Gurková, lucie.gurkova@ugn.cas.cz, Tel.: 596 979 354
    Rok sběru2017
    Elektronická adresahttp://www.sciencedirect.com/science/article/pii/S1877705816311699