Počet záznamů: 1  

Experimental quantification of useful and parasitic absorption of light in plasmon-enhanced thin silicon films for solar cells application

  1. 1.
    SYSNO ASEP0458934
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevExperimental quantification of useful and parasitic absorption of light in plasmon-enhanced thin silicon films for solar cells application
    Tvůrce(i) Morawiec, S. (IT)
    Holovský, Jakub (FZU-D) RID, ORCID
    Mendes, M.A. (IT)
    Müller, Martin (FZU-D) RID, ORCID
    Ganzerová, Kristína (FZU-D) RID
    Vetushka, Aliaksi (FZU-D) RID, ORCID
    Ledinský, Martin (FZU-D) RID, ORCID, SAI
    Priolo, F. (IT)
    Fejfar, Antonín (FZU-D) RID, ORCID, SAI
    Crupi, I. (IT)
    Číslo článku22481
    Zdroj.dok.Scientific Reports. - : Nature Publishing Group - ISSN 2045-2322
    Roč. 6, Mar (2016), 1-10
    Poč.str.10 s.
    Jazyk dok.eng - angličtina
    Země vyd.GB - Velká Británie
    Klíč. slovananoparticles ; nanophotonics and plasmonics ; solar cells ; solar energy and photovoltaic technology
    Vědní obor RIVBM - Fyzika pevných látek a magnetismus
    CEPLM2015087 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    GA14-15357S GA ČR - Grantová agentura ČR
    GA13-12386S GA ČR - Grantová agentura ČR
    Institucionální podporaFZU-D - RVO:68378271
    UT WOS000371227900001
    EID SCOPUS84960171786
    DOI10.1038/srep22481
    AnotacePhotocurrent and photothermal spectroscopy are used to quantify the useful and parasitic light absorption in hydrogenated microcrystalline silicon (μc-Si:H) films with optimized metal nanoparticle arrays, located at the rear surface, for improved light trapping via resonant plasmonic scattering. The photothermal technique accounts for the total absorptance and the photocurrent signal accounts only for the photons absorbed in the μc-Si:H layer (useful absorptance). For a 0.9 μm thick absorber layer the optical losses related to the plasmonic light trapping are insignificant below 730 nm. An average useful absorption of 43% and an average parasitic absorption of 19% over 400–1100 nm wavelength range is measured for μc-Si:H films on self-assembled Ag nanoparticles coupled with a flat mirror (plasmonic back reflector). Enhancement of useful absorption resulted in the achievement of 91% of the maximum theoretical Lambertian limit.
    PracovištěFyzikální ústav
    KontaktKristina Potocká, potocka@fzu.cz, Tel.: 220 318 579
    Rok sběru2017
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.