Počet záznamů: 1  

Comparative evaluation of acoustic techniques for detection of damages in historical wood

  1. 1.
    SYSNO ASEP0458722
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevComparative evaluation of acoustic techniques for detection of damages in historical wood
    Tvůrce(i) Kloiber, Michal (UTAM-F) RID, ORCID, SAI
    Reinprecht, L. (SK)
    Hrivnák, Jaroslav (UTAM-F)
    Tippner, J. (CZ)
    Celkový počet autorů4
    Zdroj.dok.Journal of Cultural Heritage. - : Elsevier - ISSN 1296-2074
    Roč. 20, July-August (2016), s. 622-631
    Poč.str.10 s.
    Forma vydáníTištěná - P
    Jazyk dok.eng - angličtina
    Země vyd.FR - Francie
    Klíč. slovahistorical wood ; damages ; inspection ; acoustic techniques ; mechanical properties
    Vědní obor RIVAL - Umění, architektura, kulturní dědictví
    CEPED1.1.00/02.0060 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    LO1219 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    DG16P02M026 GA MK - Ministerstvo kultury
    UT WOS000381707500007
    EID SCOPUS84960538931
    DOI10.1016/j.culher.2016.02.009
    AnotaceThis study assesses the suitability and sensitivity of select acoustic devices (Arborsonic Decay Detector, Fakopp Ultrasonic Timer with two types of sensors–TD45 and US10, and Fakopp 2D) for identification of damage in seven approximately 315 year old fir joining beams acquired during the reconstruction of the Baroque truss in the St. Mary of the Assumption Church in Vranov nad Dyjí, Czech Republic. The particular acoustic devices did not always provide similar results. However, brown rot and other inner damages in fir beams, located closer to their endings situated on masonry and connected with rafters, were determined with all acoustic devices. The possibility of indirect prediction of the strength, elasticity and hardness of the historical wood by means of the acoustic method was verified by correlation analyses, however, not seldom without higher significance. Generally, the results obtained indicate that it is not possible to fully rely on in situ acoustic methods for inspection of defects in wooden elements of historical structures, and therefore they should be combined with visual inspection and some other instrumental method(s).
    PracovištěÚstav teoretické a aplikované mechaniky
    KontaktKulawiecová Kateřina, kulawiecova@itam.cas.cz, Tel.: 225 443 285
    Rok sběru2017
    Elektronická adresahttp://www.sciencedirect.com/science/article/pii/S1296207416300103
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.