Voltammetric detection of phytochelatin transported across unmodified and protoplast modified model phospholipid membranes

  1. 1.
    SYSNO ASEP0453597
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevVoltammetric detection of phytochelatin transported across unmodified and protoplast modified model phospholipid membranes
    Tvůrce(i) Navrátil, Tomáš (UFCH-W) RID, ORCID
    Nováková, Kateřina (UFCH-W) RID
    Josypčuk, Bohdan (UFCH-W) RID, SAI, ORCID
    Sokolová, Romana (UFCH-W) RID, ORCID, SAI
    Šestáková, Ivana (UFCH-W) RID
    Zdroj.dok.Monatshefte fur Chemie. - : Springer - ISSN 0026-9247
    Roč. 147, č. 1 (2016), s. 165-171
    Poč.str.7 s.
    Jazyk dok.eng - angličtina
    Země vyd.AT - Rakousko
    Klíč. slovaBarley protoplasts ; electrochemical impendance spectroscopy ; mercury electrode
    Vědní obor RIVCG - Elektrochemie
    CEPGAP208/12/1645 GA ČR - Grantová agentura ČR
    Institucionální podporaUFCH-W - RVO:61388955
    UT WOS000367521400022
    EID SCOPUS84952802915
    DOI10.1007/s00706-015-1591-8
    AnotacePossibility of phytochelatin PC2 transport was
    examined using developed electrochemical cell with two
    compartments separated by a phospholipid membrane
    created in pores of polycarbonate support. At first cell
    penetrating peptides (transportan 10 and mastoparan X)
    were used to allow the transfer of phytochelatin PC2. The
    results demonstrated that transportan 10 is several times
    more efficient than mastoparan X for transferring of phytochelatin
    across model membrane. Voltammetry with
    hanging mercury drop electrode or with solid amalgam
    electrodes was applied for detection of transported species.
    For determination of PC2, hanging mercury drop electrode
    and mercury meniscus-modified silver solid amalgam
    electrode were suitable. Modified model phospholipid
    membrane was prepared with parts of protoplasts from
    barley roots or leaves, and transport of phytochelatin PC2
    has been confirmed. Electrochemical impedance spectroscopy
    was utilized to monitor formation, stability, and
    qualitatively the transporting process across the supported
    phospholipid membranes.
    PracovištěÚstav fyzikální chemie J.Heyrovského
    KontaktMichaela Knapová, michaela.knapova@jh-inst.cas.cz, Tel.: 266 053 196
    Rok sběru2017