Počet záznamů: 1  

Gold volatile species atomization and preconcentration in quartz devices for atomic absorption spectrometry

  1. 1.
    SYSNO ASEP0440563
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevGold volatile species atomization and preconcentration in quartz devices for atomic absorption spectrometry
    Tvůrce(i) Arslan, Y. (TR)
    Musil, Stanislav (UIACH-O) RID, ORCID
    Matoušek, Tomáš (UIACH-O) RID, ORCID
    Kratzer, Jan (UIACH-O) RID, ORCID
    Dědina, Jiří (UIACH-O) RID, ORCID
    Celkový počet autorů5
    Zdroj.dok.Spectrochimica Acta Part B: Atomic Spectroscopy. - : Elsevier - ISSN 0584-8547
    103-104, JAN-FEB (2015), s. 155-163
    Poč.str.9 s.
    Forma vydáníTištěná - P
    Jazyk dok.eng - angličtina
    Země vyd.NL - Nizozemsko
    Klíč. slovagold ; volatile species generation ; quartz atomizers ; atomic absorption spectrometry
    Vědní obor RIVCB - Analytická chemie, separace
    CEPGA14-23532S GA ČR - Grantová agentura ČR
    Institucionální podporaUIACH-O - RVO:68081715
    UT WOS000349574200021
    DOI10.1016/j.sab.2014.12.007
    AnotaceThe on-line atomization of gold volatile specieswas studied and the resultswere comparedwith thermodynamic calculations in several quartz atomizers, namely: diffusion flame, flame-in-gas-shield, flame-in-plain-tube, externally heated T-tube and externally heated flame-in-T-tube. Atomization mechanism in the explored devices is proposed, where volatile species are converted to thermodynamically stable AuH at elevated temperature over 500 °C and then atomized by an interaction with a cloud of hydrogen radicals. Because of its inherent simplicity and robustness, diffusion flame was employed as a reference atomizer. It yielded atomization efficiency of 70 to 100% and a very good long time reproducibility of peak area sensitivity: 1.6 to 1.8 s μg−1. Six and eleven times higher sensitivity, respectively, was provided by atomizers with longer light paths in the observation volume, i.e. externally heated T-tube and externally heated flame-in-T-tube. The latter one, offering limit of detection below0.01 μgml−1, appeared as the most prospective for on-line atomization. Insight into themechanismof atomization of gold volatile species, into the fate of free atoms and into subsequent analyte transfer allowed to assess possibilities of in-atomizer preconcentration of gold volatile species: it is unfeasible with quartz atomizers but a sapphire tube atomizer could be useful in this respect.
    PracovištěÚstav analytické chemie
    KontaktIveta Drobníková, drobnikova@iach.cz, Tel.: 532 290 234
    Rok sběru2015
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.