Electrolysis in electromembrane extractions. Effects on extraction performance for substituted phenols

  1. 1.
    SYSNO ASEP0438022
    Druh ASEPC - Konferenční příspěvek (mezinárodní konf.)
    Zařazení RIVD - Článek ve sborníku
    NázevElectrolysis in electromembrane extractions. Effects on extraction performance for substituted phenols
    Tvůrce(i) Šlampová, Andrea (UIACH-O) RID
    Kubáň, Pavel (UIACH-O) RID, ORCID
    Boček, Petr (UIACH-O) RID
    Celkový počet autorů3
    Zdroj.dok.CECE 2014. 11th International Interdisciplinary Meeting on Bioanalysis. - Brno : Institute of Analytical Chemistry AS CR, 2014 / Foret F. ; Křenková J. ; Drobníková I. ; Guttman A. ; Klepárník K. - ISBN 978-80-904959-2-0
    Rozsah strans. 394-396
    Poč.str.3 s.
    Forma vydáníTištěná - P
    AkceCECE 2014. International Interdisciplinary Meeting on Bioanalysis /11./
    Datum konání20.10.2014-22.10.2014
    Místo konáníBrno
    ZeměCZ - Česká republika
    Typ akceWRD
    Jazyk dok.eng - angličtina
    Země vyd.CZ - Česká republika
    Klíč. slovaelectromembrane extraction ; electrolysis ; capillary electrophoresis
    Vědní obor RIVCB - Analytická chemie, separace
    CEPGA13-05762S GA ČR - Grantová agentura ČR
    Institucionální podporaUIACH-O - RVO:68081715
    UT WOS000354547400127
    AnotaceElectrolysis was shown to play a significant role in electromembrane extraction (EME) performance. Alkaline acceptors, prepared as 1 – 10 mM CsOH solutions, suffered from electrolytic reactions during EMEs of substituted phenols and their pH values decreased by more than 8 units after 40 min of EMEs at 50 V. As a consequence, serious deterioration of EME performance was observed for weak and medium-strong acidic phenols due to their compromised ionization and their subsequent back-extraction into organic phase and donor solution. Application of acceptor solutions consisting of high concentrations of weak bases (e.g. 500 mM ethanolamine) ensured similar initial pH conditions as for the alkali-metal hydroxide based solutions, moreover, significantly better tolerance to electrolysis-induced effects was obtained. Stable pH of acceptor solutions was achieved as well as an improved EME performance for all analytes over the entire extraction period.