Počet záznamů: 1  

The precision of DCE-MRI using the tissue homogeneity model with continuous formulation of the perfusion parameters

  1. 1.
    SYSNO ASEP0431811
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevThe precision of DCE-MRI using the tissue homogeneity model with continuous formulation of the perfusion parameters
    Tvůrce(i) Bartoš, Michal (UTIA-B) ORCID
    Jiřík, Radovan (UPT-D) RID, ORCID, SAI
    Kratochvíla, Jiří (UPT-D) RID, ORCID, SAI
    Standara, M. (CZ)
    Starčuk jr., Zenon (UPT-D) RID, ORCID, SAI
    Torfinn, T. (NO)
    Celkový počet autorů6
    Zdroj.dok.Magnetic Resonance Imaging. - : Elsevier - ISSN 0730-725X
    Roč. 32, č. 5 (2014), s. 505-513
    Poč.str.9 s.
    Forma vydáníTištěná - P
    Jazyk dok.eng - angličtina
    Země vyd.US - Spojené státy americké
    Klíč. slovadynamic contrast-enhanced MRI (DCE-MRI) ; perfusion ; parameter estimation ; bolus arrival time
    Vědní obor RIVFS - Lékařská zařízení, přístroje a vybavení
    CEPGAP102/12/2380 GA ČR - Grantová agentura ČR
    ED0017/01/01 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    LO1212 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    Institucionální podporaUTIA-B - RVO:67985556 ; UPT-D - RVO:68081731
    UT WOS000335422800015
    EID SCOPUS84899052979
    DOI10.1016/j.mri.2014.02.003
    AnotaceThe present trend in dynamic contrast-enhanced MRI is to increase the number of estimated perfusion parameters using complex pharmacokinetic models. However, less attention is given to the precision analysis of the parameter estimates. In this paper, the distributed capillary adiabatic tissue homogeneity pharmacokinetic model is extended by the bolus arrival time formulated as a free continuous parameter. With the continuous formulation of all perfusion parameters, it is possible to use standard gradient-based optimization algorithms in the approximation of the-tissue concentration time sequences. This new six-parameter model is investigated by comparing Monte-Carlo simulations with theoretically derived covariance matrices. The covariance-matrix approach is extended from the usual analysis of the primary perfusion parameters of the pharmacokinetic model to the analysis of the perfusion parameters derived from the primary ones. The results indicate that the precision of the estimated perfusion parameters can be described by the covariance matrix for signal-to-noise ratio higher than similar to 20 dB. The application of the new analysis model on a real DCE-MRI data set is also presented.
    PracovištěÚstav přístrojové techniky
    KontaktMartina Šillerová, sillerova@ISIBrno.Cz, Tel.: 541 514 178
    Rok sběru2015
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.