Počet záznamů: 1  

Effect of irradiation symmetry of CO2 laser on mode coupling in long-period gratings inscribed in photonic crystal fiber

  1. 1.
    SYSNO ASEP0396748
    Druh ASEPC - Konferenční příspěvek (mezinárodní konf.)
    Zařazení RIVD - Článek ve sborníku
    NázevEffect of irradiation symmetry of CO2 laser on mode coupling in long-period gratings inscribed in photonic crystal fiber
    Tvůrce(i) Tian, F. (US)
    Kaňka, Jiří (URE-Y)
    Zou, B. (HK)
    Chiang, K.S. (HK)
    Du, H. (US)
    Celkový počet autorů5
    Zdroj.dok.FIBER OPTIC SENSORS AND APPLICATIONS X (Proceedings of SPIE 8722), 8722. - BELLINGHAM : SPIE, 2013 / Udd E. ; Pickrell G. ; Du H.H. - ISSN 0277-786X - ISBN 978-0-8194-9513-6
    Poč.str.8 s.
    Forma vydáníNosič - C
    AkceConference on Fiber Optic Sensors and Applications X
    Datum konání02.05.2013-03.05.2013
    Místo konáníBaltimore
    ZeměUS - Spojené státy americké
    Typ akceWRD
    Jazyk dok.eng - angličtina
    Země vyd.US - Spojené státy americké
    Klíč. slovaPhotonic crystal fiber ; long-period grating ; mode coupling
    Vědní obor RIVJA - Elektronika a optoelektronika, elektrotechnika
    CEPLD11030 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    Institucionální podporaURE-Y - RVO:67985882
    UT WOS000323340200012
    DOI10.1117/12.2016194
    AnotaceLong-period gratings (LPG) are inscribed in endlessly single mode (ESM) photonic crystal fiber (PCF) and conventional single mode fiber (SMF) with symmetric and asymmetric CO2 laser irradiation. Transmission measurements and near-field imaging indicate that symmetric index perturbation induced by laser irradiation with the aid of a 120 degrees gold-coated reflecting mirror results in LP0n symmetric mode coupling, while asymmetric irradiation without using the mirror leads to LP1n asymmetric mode coupling for both fiber types. Symmetric irradiation yields far more reproducible LPG in PCF than asymmetric irradiation. On the other hand, the irradiation symmetry has little effect on the reproducibility of LPG inscribed in SMF due to the isotropy of its all-solid cladding structure. The removal of the outer solid cladding of PCF-LPG results in a significant change in its transmission characteristics, which provides rich information on the refractive index perturbation and mode field distribution in the outer solid cladding of PCF-LPG
    PracovištěÚstav fotoniky a elektroniky
    KontaktPetr Vacek, vacek@ufe.cz, Tel.: 266 773 413, 266 773 438, 266 773 488
    Rok sběru2014
Počet záznamů: 1  