Počet záznamů: 1  

Reduced-Order Square-Root EKF for Sensorless Control of PMSM Drives

  1. 1.
    SYSNO ASEP0368814
    Druh ASEPC - Konferenční příspěvek (mezinárodní konf.)
    Zařazení RIVD - Článek ve sborníku
    NázevReduced-Order Square-Root EKF for Sensorless Control of PMSM Drives
    Tvůrce(i) Šmídl, Václav (UTIA-B) RID, ORCID
    Peroutka, Z. (CZ)
    Zdroj.dok.Proceedings of the 37th Annual Conference of the IEEE Industrial Electronics Society. - Piscataway : IEEE, 2011 - ISSN 1553-572X - ISBN 978-1-61284-971-3
    Rozsah strans. 1929-1934
    Poč.str.6 s.
    Forma vydáníwww - www
    AkceIEEE Industrial Electronics, IECON 2011 - 37th Annual Conference on
    Datum konání07.11.2011-10.11.2011
    Místo konáníMelbourne
    ZeměAU - Austrálie
    Typ akceWRD
    Jazyk dok.eng - angličtina
    Země vyd.US - Spojené státy americké
    Klíč. slovasensorless control ; square root EKF ; PMSM drive
    Vědní obor RIVJA - Elektronika a optoelektronika, elektrotechnika
    CEPGAP102/11/0437 GA ČR - Grantová agentura ČR
    CEZAV0Z10750506 - UTIA-B (2005-2011)
    UT WOS000299032402033
    DOI10.1109/IECON.2011.6119446
    AnotacePerformance of square-root extended Kalman filter (EKF) based on reduced order models for sensorless control of permanent magnet synchronous motor (PMSM) drives is studied. The reduced order model of PMSM has two-dimensional state vector comprising of: (i) electrical rotor speed, and (ii) electrical rotor position. These state quantities are estimated by the EKF without either speed or position sensor on the motor shaft. The reduction of the model order results in dramatic speed-up of calculation of the estimator which takes only a few tens of microseconds on a conventional fixed-point digital signal processor. Accuracy of the estimator is improved using square-root representation of the covariance matrix. Due to its low computationalrequirements, the proposed square-root EKF estimator is eligible for sophisticated diagnostics as well for sensorless control of PMSM drive in a wide range of industrial applications. Presented theoretical conclusions are verified by both simulations and experiments carried out on developed PMSM drive prototype of rated power of 10.7kW.
    PracovištěÚstav teorie informace a automatizace
    KontaktMarkéta Votavová, votavova@utia.cas.cz, Tel.: 266 052 201.
    Rok sběru2012
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.