Počet záznamů: 1
Simulation of the Mechanical Behaviour of a Single Human Trabecula assessed with a Micromechanical Test and Nanoindentation
- 1.
SYSNO ASEP 0364803 Druh ASEP C - Konferenční příspěvek (mezinárodní konf.) Zařazení RIV D - Článek ve sborníku Název Simulation of the Mechanical Behaviour of a Single Human Trabecula assessed with a Micromechanical Test and Nanoindentation Tvůrce(i) Jiroušek, Ondřej (UTAM-F) RID, SAI
Kytýř, Daniel (UTAM-F) SAI, RID, ORCID
Kunecký, Jiří (UTAM-F) RID, SAI, ORCID
Zlámal, Petr (UTAM-F) RID, SAI, ORCID
Doktor, Tomáš (UTAM-F) RID, SAI, ORCID
Němeček, J. (CZ)Celkový počet autorů 6 Zdroj.dok. Proceedings of the Thirteenth International Conference on Civil, Structural and Environmental Engineering Computing. - Kippen : Civil-Comp Press, 2011 / B.H.V. Topping ; Y. Tsompanakis - ISSN 1759-3433 - ISBN 978-1-905088-46-1 Rozsah stran s. 238-249 Poč.str. 12 s. Forma vydání cd-rom - cd-rom Akce International Conference on Civil, Structural and Environmental Engineering Computing /13./ Datum konání 06.09.2011-09.09.2011 Místo konání Chania Země GR - Řecko Typ akce WRD Jazyk dok. eng - angličtina Země vyd. GB - Velká Británie Klíč. slova trabecular bone ; nanoindentation ; micromechanical testing ; optical strain measurement ; constitutive models ; finite element modelling Vědní obor RIV JJ - Ostatní materiály CEP GAP105/10/2305 GA ČR - Grantová agentura ČR CEZ AV0Z20710524 - UTAM-F (2005-2011) Anotace The paper presents a comparison between mechanical properties of single human trabeculae obtained by micromechanical testing and those assessed by nanoindentation. Compact uniaxial tension/compression device has been developed for this purpose. The strains at the surface of the sample are measured optically using a high-resolution CCD camera. The strain field is evaluated using image correlation technique. Local micromechanical properties were assessed using nanoindentation. From obtained nanoindentation curves material parameters for elasto--plastic constitutive model with isotropic hardening are identified in a FE simulation of the indentation process. The unknown parameters are identified in a large set of parametric studies in which the response of the model is best-fitted to the experimental curve. Validation of the material model obtained from nanoindentation is presented in simulation of the tensile test of single trabecula. Pracoviště Ústav teoretické a aplikované mechaniky Kontakt Kulawiecová Kateřina, kulawiecova@itam.cas.cz, Tel.: 225 443 285 Rok sběru 2012
Počet záznamů: 1