Počet záznamů: 1  

Full characterization of laser-accelerated ion beams using Faraday cup, silicon carbide, and single-crystal diamond detectors

  1. 1.
    SYSNO ASEP0364302
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevFull characterization of laser-accelerated ion beams using Faraday cup, silicon carbide, and single-crystal diamond detectors
    Tvůrce(i) Margarone, Daniele (FZU-D) RID, ORCID
    Krása, Josef (FZU-D) RID, ORCID
    Giuffrida, L. (IT)
    Picciotto, A. (IT)
    Torrisi, L. (IT)
    Nowak, T. (PL)
    Musumeci, P. (IT)
    Velyhan, Andriy (FZU-D) RID, ORCID
    Prokůpek, Jan (FZU-D) RID
    Láska, Leoš (FZU-D)
    Mocek, Tomáš (FZU-D) RID, ORCID, SAI
    Ullschmied, Jiří (UFP-V) RID
    Rus, Bedřich (FZU-D) ORCID
    Zdroj.dok.Journal of Applied Physics. - : AIP Publishing - ISSN 0021-8979
    Roč. 109, č. 10 (2011), "103302-1"-"103302-8"
    Poč.str.8 s.
    Jazyk dok.eng - angličtina
    Země vyd.US - Spojené státy americké
    Klíč. slovaaluminium ; chemical sensors ; diamond ; electrostatics ; iodine ; ion beams ; thin films ; lasers ; time of flight spectrometers
    Vědní obor RIVBH - Optika, masery a lasery
    CEPGAP205/11/1165 GA ČR - Grantová agentura ČR
    7E09092 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    CEZAV0Z10100523 - FZU-D (2005-2011)
    AV0Z20430508 - UFP-V (2005-2011)
    UT WOS000292115900043
    DOI10.1063/1.3585871
    AnotaceReal-time ion diagnostics have been performed by the use of various time-of-flight (TOF) detectors: ion collectors (ICs) with and without absorber thin films, new prototypes of single-crystal diamond and silicon carbide detectors, and an electrostatic ion mass spectrometer (IEA). In order to suppress the long photopeak induced by soft X-rays and to avoid the overlap with the signal from ultrafast particles, the ICs have been shielded with Al foil filters. The application of large-bandgap semiconductor detectors (>3 eV) ensured cutting of the plasma-emitted visible and soft-UV radiation and enhancing the sensitivity to the very fast proton/ion beams. Employing the IEA spectrometer, various ion species and charge states in the expanding laser-plasma have been determined.