Počet záznamů: 1  

Interlock system for the COMPASS tokamak

  1. 1.
    SYSNO ASEP0349232
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevInterlock system for the COMPASS tokamak
    Tvůrce(i) Hron, Martin (UFP-V) RID, ORCID
    Sova, J. (CZ)
    Šíba, J. (CZ)
    Kovář, J. (CZ)
    Adámek, Jiří (UFP-V) RID, ORCID
    Pánek, Radomír (UFP-V) RID
    Havlíček, Josef (UFP-V) RID, ORCID
    Písačka, Jan (UFP-V) RID
    Mlynář, Jan (UFP-V) RID
    Stöckel, Jan (UFP-V) RID
    Zdroj.dok.Fusion Engineering and Design. - : Elsevier - ISSN 0920-3796
    Roč. 85, 3-4 (2010), s. 505-508
    Poč.str.4 s.
    Forma vydáníweb - web
    AkceIAEA Technical Meeting on Control, Data Acquisition and Remote Participation for Fusion Research/7th./
    Datum konání15.06.2009-19.06.2009
    Místo konáníAix – en – Provence
    ZeměFR - Francie
    Typ akceWRD
    Jazyk dok.eng - angličtina
    Země vyd.CH - Švýcarsko
    Klíč. slovaTokamak operation ; Interlock ; Personnel safety
    Vědní obor RIVBL - Fyzika plazmatu a výboje v plynech
    CEP7G09042 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    GD202/08/H057 GA ČR - Grantová agentura ČR
    CEZAV0Z20430508 - UFP-V (2005-2011)
    UT WOS000281190000051
    DOI10.1016/j.fusengdes.2010.03.054
    AnotaceThe COMPASS tokamak has started its operation recently at the Institute of Plasma Physics ASCRin Prague, Czech Republic. An important issue of the operation is the interlock system, which secures the safety of the personnel. The personnel protection is based on a restricted access into the experimental hall during the tokamak operation. An experimental hall access system, based on Honeywell WIN-PAKTM2005, allows to set the status of the experimental area and to control the movement of the personnel. A hardware interlock, based on a PLC connected on PESNET bus, interprets the experimental hall status and controls the safety of the operation of key systems accordingly. The permit for operation is granted and the real status of the systems is reported by hard-wired potential-less contacts. Visualization PC creates an operator interface, on which is running a .NET application; this PC is connected with PLC via PESNET bus. Details of the set-up are described in this contribution.
    PracovištěÚstav fyziky plazmatu
    KontaktVladimíra Kebza, kebza@ipp.cas.cz, Tel.: 266 052 975
    Rok sběru2011
Počet záznamů: 1  