Polymethacrylate Monolithic and Hybrid Particle-Monolithic Columns for Reversed-Phase and Hydrophilic Interaction Capillary Liquid Chromatography

  1. 1.
    SYSNO ASEP0335333
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevPolymethacrylate Monolithic and Hybrid Particle-Monolithic Columns for Reversed-Phase and Hydrophilic Interaction Capillary Liquid Chromatography
    Překlad názvuPolymetakrylátové monolitické a hybridní částicové monolitické kolony pro kapilární kapalinovou chromatografii v systému s obrácenými fázemi a chromatografii hydrofilních interakcí
    Tvůrce(i) Jandera, P. (CZ)
    Urban, J. (CZ)
    Škeříková, V. (CZ)
    Langmeier, P. (CZ)
    Kubíčková, R. (CZ)
    Planeta, Josef (UIACH-O) RID, ORCID
    Celkový počet autorů6
    Zdroj.dok.Journal of Chromatography A. - : Elsevier - ISSN 0021-9673
    Roč. 1217, č. 1 (2010), s. 22-33
    Poč.str.12 s.
    ZeměUS - Spojené státy americké
    Jazyk dok.eng - angličtina
    Země vyd.NL - Nizozemsko
    Klíč. slovaparticle-monolithic columns ; hybrid columns ; polymethacrylate monoliths ; capillary HPLC ; HILIC ; proteins ; phenolic acids
    Vědní obor RIVCB - Analytická chemie, separace
    CEPGA203/08/1536 GA ČR - Grantová agentura ČR
    CEZAV0Z40310501 - UIACH-O (2005-2011)
    UT WOS000273623100004
    DOI1016/j.chroma.2009.09.041
    AnotaceWe prepared hybrid particle-monolithic polymethacrylate columns for micro-HPLC by in situ polymerization in fused silica capillaries pre-packed with 3–5m C18 and aminopropyl silica bonded particles, using polymerization mixtures based on laurylmethacrylate–ethylene dimethacrylate (co)polymers for the reversed-phase (RP) mode and [2-(methacryloyloxy)ethyl]- dimethyl-(3-sulfopropyl) zwitterionic (co)polymers for the hydrophilic interaction (HILIC) mode. The hybrid particle-monolithic columns showed reduced porosity and hold-up volumes, approximately 2– 2.5 times lower in comparison to the pure monolithic columns prepared in the whole volume of empty capillaries. The elution volumes of sample compounds are also generally lower in comparison to packed or pure monolithic columns. The efficiency and permeability of the hybrid columns are intermediate in between the properties of the reference pure monolithic and particle-packed columns.
    PracovištěÚstav analytické chemie