Počet záznamů: 1  

Novel instrumentation for interferometric nanoscale comparator

  1. 1.
    SYSNO ASEP0335088
    Druh ASEPC - Konferenční příspěvek (mezinárodní konf.)
    Zařazení RIVD - Článek ve sborníku
    NázevNovel instrumentation for interferometric nanoscale comparator
    Tvůrce(i) Čížek, Martin (UPT-D) RID, ORCID, SAI
    Buchta, Zdeněk (UPT-D) RID, SAI, ORCID
    Mikel, Břetislav (UPT-D) RID, SAI
    Lazar, Josef (UPT-D) RID, ORCID, SAI
    Číp, Ondřej (UPT-D) RID, SAI, ORCID
    Celkový počet autorů5
    Zdroj.dok.Optical Measurement Systems for Industrial Inspection VI. (Proceedings of SPIE Vol. 7389). - Bellingham : SPIE, 2009 - ISSN 0277-786X - ISBN 978-0-8194-7672-2
    Rozsah stran73982y: 1-7
    Poč.str.7 s.
    AkceOptical Measurement Systems for Industrial Inspection /6./
    Datum konání14.06.2009-18.06.2009
    Místo konáníMunich
    ZeměDE - Německo
    Typ akceWRD
    Jazyk dok.eng - angličtina
    Země vyd.US - Spojené státy americké
    Klíč. slovahigh resolution interferometry ; laser comparator ; precision displacement sensors
    Vědní obor RIVBH - Optika, masery a lasery
    CEPGA102/09/1276 GA ČR - Grantová agentura ČR
    LC06007 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    2C06012 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    2A-1TP1/127 GA MPO - Ministerstvo průmyslu a obchodu
    FT-TA3/133 GA MPO - Ministerstvo průmyslu a obchodu
    2A-3TP1/113 GA MPO - Ministerstvo průmyslu a obchodu
    GA102/07/1179 GA ČR - Grantová agentura ČR
    GP102/09/P630 GA ČR - Grantová agentura ČR
    KAN311610701 GA AV ČR - Akademie věd
    CEZAV0Z20650511 - UPT-D (2005-2011)
    DOI10.1117/12.827515
    AnotacePresented paper deals with the description of subsystems of a novel interferometric nanocomparator. High speed digital quadrature detector based on digital signal controller is used here for processing of the X-Y signals from the detection unit of the interferometer. Digital filtering increases signal to noise ratio and allows achievement of sub-nanometer resolution and accuracy of the laser interferometer. The refractive index of the air is computed continuously from the current atmospheric values using Edlen's formula. High dynamic range of the mirror displacement setting is achieved using a two stage positioning system formed of a linear guide way and piezoelectric actuators. The linear guide way is used for open-loop coarse positioning with 50 nm accuracy and up to 100 mm of displacement. Piezoelectric actuators in servo-loop linked to the interferometer value are used for fine positioning with better than 1 nm accuracy over a 5 μm range.
    PracovištěÚstav přístrojové techniky
    KontaktMartina Šillerová, sillerova@ISIBrno.Cz, Tel.: 541 514 178
    Rok sběru2010
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.